Source Technologies ST9530 User Manual

Page of 70
Secure MICR Printer User’s Guide 
 
 
© Source Technologies 
September 2005 
26
 
 
All Rights Reserved 
Both commands require the MICR Password Command.  The ON command blocks the 
copy function with MICR toner.  The OFF command allows the copy function with MICR 
toner.  The factory default is OFF 
 
Note – Postscript Language print jobs downloaded from a host will not print with MICR 
toner if the Postscript job contains a copy count command.  Copy Defeat = ON will reset 
copy count to 0, and nothing prints. Either the Copy Defeat function needs to be set to OFF 
or the copy count command needs to be removed if the user requires Postscript MICR 
printing.  We tested a few Postscript printer drivers and did not detect copy count 
commands, but the specific data streams should be tested.     
 
Customer Character Conversation Command
 
 
The Custom Character Conversion Command can be used to resolve some problems in 
printer data streams.  An example might be to remove a special command character in an 
existing data stream that was used by your previous printer hardware.  Without changing 
your data stream, these special characters can either be removed, converted to Nulls, or 
converted to other sets of data to accomplish what is required. 
 
An example of this might convert a Skip Command used by an older generation printer to 
multiple Carriage Return / Line Feed commands.  You could also store a PCL5 command 
in our SIMM and call it with one character in your data stream.  Only one type of conversion 
is permitted at any particular point in time, but the function can be modified within a data 
stream multiple times.   
 
The conversion information is stored in NVRAM and is retained through power off / power 
on cycles.  This means you could send the command one time and all future print jobs 
would be converted.  Special precautions are required if printer fonts and Macro’s are 
downloaded to your printer.  This might require you to disable the function during 
downloads and re-enable prior to your print data. 
 
&%STCxx[yy...]$ 
xx is a double-byte character to convert - the following characters are 
not 
allowed: 
 
 
    
 
&, %, S, T, C and $. 
 
yy...is a double-byte string to convert to - can be 0 to 16 characters 
long 
 
   $ 
command 
terminator 
 
Example: 
 
&%STC1E0D0A$  sets the convert character to 1E - the printer will replace any 1E 
character in the data stream with 0D 0A (carriage return, line feed)