Source Technologies ST9530 User Manual

Page of 70
Secure MICR Printer User’s Guide 
 
 
© Source Technologies 
September 2005 
38
 
 
All Rights Reserved 
$ Command 
terminator 
 
Ends the Audit Record and the PJL job (ignored if there was no Start Audit Record 
Command). 
      
Audit Report Field One 
&%SQ1d..d$
 
&%SQ1 
Lead in sequence 
d..d 
Data to be stored 
$ Command 
terminator 
 
This command identifies the data to be printed in the first column of the report.  It is a 
maximum of 14 characters in length.  If less than 14 characters are sent, the printer fills the 
field with spaces when the audit report is printed. This field is recorded in the audit report 
only, it is not printed on the check. 
 
Audit Report Field Two-MICR Line 
&%SMDd..d$ or &%SM7d..d$
 
&%SMD or &%SM7 
   
Lead in sequence 
d..d 
   
Data to be printed 
$  
 
Command 
terminator 
 
This command identifies the data to be printed in the second column of the report.  It is a 
maximum of 40 characters in length. 
 
Audit Report Field Three 
&%SQ3d..d$
 
&%SQ3 
Lead in sequence 
 
d..d 
Data to be printed 
$ Command 
terminator 
 
This command identifies the data to be printed in the third column of the report.  It is a 
maximum of 40 characters. 
 
Audit Report Field Four 
&%SQ4d..d~
 
&%SQ4 
Lead in sequence 
d..d 
Data to be printed 
~ Command 
terminator 
 
This command identifies the data to be printed in the fourth column of the report.  It is a 
maximum of 16 characters in length.  Since a total of this field can be provided at the end of 
the Audit Trail Report it is typically used for the convenience amount field.  NOTE: This is the 
only command where the $ is not a command terminator. The tilde ~ (hex 7E) acts as the 
command terminator.