6.4.3  RFID PARAMETER SET COMMAND 
[ESC] Z2; 3 
 
Function 
Sets RFID related parameters on the printer. 
 
Format 
[ESC] Z2; 3, abbcdddeeeffggghhijjkkkllmnnooppq [LF] [NUL] 
 
Term 
a: 
RFID module type selection 
   
 
0: 
Not 
installed. 
1: H1 (B-9704-RFID-H1-QM) 
2: U1 (B-9704-RFID-U1-US/EU(-R)) 
3: H2 (B-SX704-RFID-H2) 
4: U2 (B-SX704-RFID-U2-EU/US/CN/AU-R) 
  bb: 
Tag 
type 
 
00: None 
11: I-Code 
12: Tag-it 
13: C220 
14: ISO15693 
15: C210 
16: C240 
17: C320 
21:  EPC Class 0 
22:  EPC Class 1 
23:  ISO 18000-6B 
24:  EPC Class 1 Generation 2 
 
 
c: 
RFID error tag detection   
(Invalid from firmware V4.7. This is programmed in the printer system mode.) 
0: Not detected. 
1: Detected. 
 
 
ddd:  Max. number of RFID issue retries 
 
 
 
  000 to 255 
 
 
 
eee:  Max. number of RFID read retries 
000 to 255   
 
 
ff: 
RFID read retry time-out 
00 to 99 (In units of 0.1 sec.: 0.0 sec. to 9.9 sec.)   
 
 
ggg:  Max. number of RFID write retries 
000 to 255 
 
 
 
hh:  RFID write retry time-out 
 
 
 
  00 to 99 (In units of 0.1 sec.: 0.0 sec. to 9.9 sec.) 
 
 
i: 
Feed direction of adjustment for retry 
+: Backward  
−: Forward 
 
 
jj: 
Feed amount of adjustment for retry 
 
 
 
  00 to 99 (In units of 1 mm: 0 mm to 99 mm) 
Only the value of 
−3 mm or less, or +3 mm or more becomes effective. 
 
 
kkk: 
RFID wireless power level 
000 to 255