Qqrstuvw:  Area lock designation (Effective only when the Hibiki tag is used for the B-
SX704-RFID-U2-R. 
Designates an area lock type. 
Area lock type can be specified for up to eight areas continuously. 
For example: Q1100000,Q4101010,Q5100010, which indicates: 
Bank1:Read lock, Bank4:Read lock, Write lock, Password read/write lock 
Bank5:Read lock, Password read/write lock   
 
 
 
q: Area bank designation (1 to 8) 
1: Bank1 (EPCC/UII bank) 
2: Bank2 (TID bank) 
3: Bank3 (User area) 
4: Bank4 (User block 1) 
5: Bank5 (User block 2) 
6: Bank6 (User block 3) 
7: Bank7 (User block 4) 
8: Bank8 (User block 5) 
 
 
 
r:  Read lock designation 
0: Disabled 
1: Enabled 
 
 
 
s: Read permanent lock designation 
0: Disabled 
1: Enabled 
 
 
 
t:  Write lock designation (Effective to Bank4 to Bank8 only) 
0: Disabled 
1: Enabled 
 
 
 
u: Write permanent lock designation (Effective to Bank4 to Bank8 only) 
0: Disabled 
1: Enabled 
 
 
 
v: User block password read/write lock designation (Effective to Bank4 to 
Bank8 only) 
0: Disabled 
1: Enabled 
 
 
 
w: User block password read/write permanent lock designation (Effective to 
Bank4 to Bank8 only) 
0: Disabled 
1: Enabled 
NOTES:  
1.  Once a permanent lock is enabled for parameter s, u, or w, any 
subsequent change is disabled. 
2.  When read/write permanent lock is selected, a read/write lock state is 
retained.  To permanently prohibit reading/writing a tag, enable both 
the read/write lock and the read/write permanent lock.    The setting 
which disables the read/write lock and enables the read/write 
permanent lock allows the tag to be read/written permanently.