Toshiba B-SX5T SERIES User Manual

Page of 56
APPENDIX 3  INTERFACE 
ENGLISH VERSION EO1-33036 
APPENDIX 3  INTERFACE 
 
EA3-1 
APPENDIX 3  INTERFACE 
„Interface Cables 
To prevent radiation and reception of electrical noise, the interface cables must meet the following requirements: 
• 
Fully shielded and fitted with metal or metallised connector housings. 
• 
Keep as short as possible. 
• 
Should not be bundled tightly with power cords. 
• 
Should not be tied to power line conduits. 
 
„RS-232C Cable description 
The serial data cable used to connect the printer to the host compute should be one of the following two types: 
 
 
 
 
 
 
 
NOTE: 
Use an RS-232C cable with the connector including inch type securing screws for the QQ model or metric type 
securing screws for the QP model.  
DB-9S 
Connector to PC
 
Pin No. 
Signal 
1 N.C. 
2 RXD 
3 TXD 
4 DTR 
5 GND 
6 DSR 
7 RTS 
8 CTS 
9 N.C. 
Housing Shield 
DB-25P 
Connector to Printer
 
Pin No. 
Signal 
1 F.G. 
2 RXD 
3 TXD 
4 CTS 
5 RTS 
6 DTR 
7 SG 
20 DSR 
 
DB-25S 
Connector to PC
 
Pin No. 
Signal 
1 Shield 
2 TXD 
3 RXD 
4 RTS 
5 CTS 
6 DSR 
7 GND 
20 DTR 
DB-25P 
Connector to Printer
 
Pin No. 
Signal 
1 F.G. 
2 RXD 
3 TXD 
4 CTS 
5 RTS 
6 DTR 
7 SG 