Toshiba e-STUDIO161 User Manual

Page of 76
TROUBLESHOOTING
48
Section C
Remove the misfed original from the exit area.
 
If the misfed original cannot be easily removed 
from the exit area, open the moveable part of the 
document feeder tray and remove the original.
 
2
Open and close the ADF to make the 
misfeed location indicator stop 
blinking.
You can also make the 
misfeed indicator stop 
blinking by opening and 
closing the feeding roller 
cover or the right side 
cover.
3
Return the originals indicated by the 
minus number in the display to the 
document feeder tray and press the 
[START] key ( ).
Copying will resume from the originals that still 
remained when the misfeed occurred.
MISFEED IN THE BYPASS TRAY
1
Gently pull the misfed paper out.
2
Open and close the side cover.
The misfeed indicator 
(
) will go out.
• When closing the side cover, press down 
on the handle.
• If the misfeed indicator (
) does not 
stop blinking, check for torn pieces of 
paper in the machine.
Note