Toshiba B-415 User Manual

Page of 32
E2-2
2. SPECIFICATIONS
ENGLISH VERSION EO1-33014
NOTE:
This printer requires an exclusive printer cable.  When purchasing it, please contact your
authorized TOSHIBA TEC representative.
Item
Description
Baud rate
9600 bps
Protocol
XON/XOFF, 8 bit data, Even parity, Stop bit = 1 bit
Signals
TXD, RXD, RTS, CTS
2.3 Serial Interface (RS-232C) (for GH24 and GH34 models)
Item
Description
Type
FM superhet UHF radio telemetry receiver (Complies with MPT1340*,
ETS300-220**)
Receiving frequency
418 MHz*, 433 MHz**
Communication method
Unidirectional (Receive only)
Transmission speed
4800 bps
Protocol
8 bit data, non parity, stop bit = 1 bit
Communicating distance
3 m
*:   GB model
**:   QP model
NOTE:
The RS-232C interface cable must be disconnected when using the radio communication.
2.5 Bluetooth Interface (for GH25 model)
2.4 Radio Interface (for GH34 model)
The following specification is applicable only to the GB and QP models.
Item
Description
Communication method
Bluetooth V1.1 (with logo certification)
Supported profile
Serial port profile
Communication class
Class 2
Communication distance
3m/360 degrees
Service name
ZV-AT
Device nickname
TOSHIBA TEC BT
Flow control
Credit based flow control
Operation mode
Slave mode
PIN code
Not used.
Receive buffer
2 K bytes
Link break time out
20 sec.
Inquiry control
No response to any inquiry can be made in 1 minute after the power is
turned ON.
SR mode at page/inquiry scanning R1 scan interval 1.28 sec.
Scan window 22.5 msec.
2.3 Serial Interface (RS-232C) (for GH24 and GH34 models)