QUICK TIPS
Auto Cutter
  SETTINGS > Autocutter = ON / OFF
Label Settings
  SETTINGS > Current Label Configuration
CLR Key
  Returns to general mode & clears all text, formats, and font settings
Navigation
  Arrows
  Moves to next / previous label = SHIFT + LEFT / RIGHT ARROWS
Numeral Selections
  TOP / BOTTOM ARROWS (Press and hold for faster speed)
   Enter number
Printing
  Multiple prints = SHIFT + PRINT
  Feed the tape = SHIFT + CUT
Insert/Remove Labels
  Insert labels = SHIFT + SAVE
  Remove labels = SHIFT + RECALL
Save/Recall Labels 
  Save labels = SAVE
  Recall labels = RECALL
Serialization 
  Simple (A1 A2 A3) = SERIAL
  Simultaneous (A1 B2 C3) = SHIFT + SERIAL > Simultaneous
  Advanced (A1 A2 B1 B2 C1 C2) = SHIFT + SERIAL > Advanced
Technical Support: (203) 588-2500
QUICK REFERENCE GUIDE
GENERAL PURPOSE LABELS
TERMINAL BLOCK LABELS
PANEL LABELS
WIRE LABELS
   
HORIZONTAL    
   
WRAP
1
  Press H. WRAP
 
                  + 
2
  Set label length: AUTO, press OK
3
  Enter text: Bedroom 1 - CATV 
4
  Press PRINT
 
   
BACK OF PATCH
   
PANEL 
(#1)
1
  Create a Patch Panel. 
 
(see Patch Panel steps 1 – 6 on page 7) 
2
  Press SHIFT + PPANEL                   +  
3
  Set # of copies to 1 
4
  Press PRINT
   
SELF-
   
LAMINATING
1
  Press SELF-LAM                    + 
2
  Set label length: AUTO, press OK
3
  Type text: A101  
4
  Press PRINT
   
  MODULE
1
  Press MODULE 
2
  Set fuse length: 0.70”, 
 
# of modules: 3, 
 
multipliers: module 1, multiplier 1,  
 
 
module 2, multiplier 1, 
  
 
module 3, multiplier 2, 
 
select DONE, press OK
3
  Enter text: Bar
4
   Press                +       one time to move to the next module
5
  Repeat steps 3 – 4 until all modules are labeled
6
  Press  PRINT 
   
FIXED 
   
LENGTH
1
  Press FIXED 
Set the label length: 3.50”, press OK
Enter text: 120 Volts 
Press PRINT
   
VERTICAL
1
  Press VERTICAL 
2
  Select label length: AUTO, press OK
3
  Enter text: RACK3 
4
  Press PRINT 
   
VERTICAL   
   
WRAP
1
  Press V. WRAP 
2
  Select type of wire - COAX, press OK
3
  Enter text: A101 
4
  Press PRINT 
   
FLAG
1
  Press FLAG 
2
  Set flag length: AUTO, press OK
3
  Press LIBRARY
4
  Select VOICE/DATA, press OK
5
  Press L, select LAN, press OK
6
  Press PRINT
 
    
BACK OF PATCH  
    
PANEL 
(#2)
1
  Press PPANEL
 
 
 
2
  Set port distance: 1.25”, # of ports: 3, select DONE, press OK
3
  Enter text: A01, press ENTER, A02
4
  Press ADV. SER.                   +  
5
  Select SIMULTANEOUS, press OK
  
6
  Select 1 to be the first character to be 
 
serialized, press OK  
7
  Select 2 to be the second character to 
 
be serialized, press OK 
 
 
8
  Set increment: 2 and # of serializations: 3, press OK  
9
 
Press SHIFT + PPANEL
                   + 
10 
Set # of copies to 1, press PRINT
 
 
   
A/V 
   
DISTRIBUTION  
   
PANEL
1
  Press PPANEL 
2
  Select port distance: 1.50” and # of ports: 3, 
 
Set DONE, press OK
3
  Enter text: MSTR BDRM 
4
  Press               +      one time to move to the next connector 
5
  Repeat steps 3 – 4 until first three ports are labeled
6
  Press INSERT                   +               , select insert 
 
next label to the right, press OK
7
  Repeat steps 3 – 6 until all ports are labeled 
8
  Press PRINT                 select all
   
TERMINAL  
    
BLOCK
1
  Press TBLOCK
2
  Set # of blocks: 8, and block size: 0.20”, 
  
select DONE, press OK
3
  Enter text: T01
4
  Press SERIAL 
5
  Select 1 to be serialized, press OK
6
  Set the increment: 1 and # of serializations: 8, 
  
press OK 
7
  Press PRINT 
   
110 TERMINAL 
   
BLOCK
1
  Press PPANEL 
2
  Set port distance: 1.20” and # of ports: 6, 
 
select DONE, press OK
 
3
 
Enter text: 10-110, press ENTER, 20-110
4
  Press ADV. SER.                   + 
5
  Select SIMULTANEOUS, press OK
6
  Select the first character to 
 
be serialized, press OK
7
  Select the second character to
 
be serialized, press OK
8
  Set increment: 1 and  
 
# of serializations: 6, press OK
9
  Press PRINT
 
   
PATCH 
   
PANEL
1
  Press PPANEL 
2
  Set port distance: 0.60” and # of ports: 6 (# of ports 
 
grouped together), select DONE, press OK
3
  Enter text: A01 
4
  Press SERIAL 
5
  Select 1 to be serialized, press OK
6
  Set increment: 1 and # of serializations: 12 (total # of     
 
ports), press OK, select DONE, press OK
7
  Press PRINT                select all
   
ELECTRICAL  
   
PANEL
1
  Press TBLOCK 
2
  Set number of blocks: 6, and block size: 1.00”, 
 
select  DONE, press OK
3
  Enter text: Bedroom 1, Press ENTER,  Hallway
4
  Press                   +       to move to next breaker label
5
  Enter text: Kitchen 
6
  Repeat steps 4 – 5 until all breakers are labeled 
7
  Press PRINT 
GENERAL PURPOSE LABELS
TERMINAL BLOCK LABELS
PANEL LABELS
WIRE LABELS
RHINO