Citizen iDP3310 User Manual

Page of 87
iDP3310 User's Manual
22
CITIZEN
6.3  Input and Output Signals
6.3.1  Input and Output Signals
(1) Input Signals to the Printer
DATA
: 8-bit parallel signal. (Positive logic)
STB
: Strobe signal to read 8-bit data. (Negative logic)
RESET
: Signal to reset the entire printer (Negative logic) 1m sec more
(2) Output Signals from Printer
ACK
: An 8-bit data request signal.  Pulse signal output at the end of the BUSY signal.(Negative
logic)
BUSY
: The signal to indicate BUSY state of the printer.  Input new data for "LOW."(Positive logic)
FAULT
: The signal which is made "LOW" when the printer is in alarm state.  All the control circuit
inside the printer are stopped at this time.(Negative logic)
SELECT : The signal which is made "HIGH" when the printer is ready to receive the data. (Positive
logic)
(3) Power related signal
GND
: This is the common ground for the circuits.