Xerox FS-C8008DN User Manual
B.4 RS-232C Protocol
B-7
B.4
RS-232C Protocol
B.4.1
Parameters of the RS-232C Protocol
A protocol is a set of rules followed by various devices to send or receive data. The
parameters of the RS-232C protocol are stored in the battery-powered memory of the
printer. You can verify these parameters on the status printout as marked by the following
identifications:
parameters of the RS-232C protocol are stored in the battery-powered memory of the
printer. You can verify these parameters on the status printout as marked by the following
identifications:
•
H1: Baud rate
•
H2: Number of data bits
•
H3: Number of stop bits
•
H4: Parity
•
H5: Protocol logic
•
H6: Buffer-nearly-full threshold
•
H7: Buffer nearly-empty threshold
•
H8: Received data buffer size
The parameters can be changed from the printer operator panel. To change the value for the
serial interface parameters, see
serial interface parameters, see
This following section outlines the parameters and their values you can select on the
operator panel:
operator panel:
H1: Baud rate
The factory setting is 96 (9600 baud).
H2: Number of data bits
7 or 8. The factory setting is 8.
H3: Number of stop bits
1 or 2. The factory setting is 1.
Parameter value
Baud rate
12
1200
24
2400
48
4800
96
9600
19
19200
38
38400
57
57600
11