Installation Preparation Document 
(for physical installation of the product only)
 
 
Xerox DocuTech 6100/6115/6135
 
 
 
701P43857 
June 2005
 
Please ensure electrical, space, and supplies are available prior to equipment delivery.
 
Customer Support 
The Xerox Customer Support Center is available to provide general 
information, answer questions, and take service calls. You can reach 
the Customer Support Center at the following toll-free phone number: 
United States 
1-800-821-2797 
Your Xerox Analyst will provide fee-based training upon request. 
 
Space Requirements
 
The diagram below is provided as a representation only of the space 
envelope required for installation of Xerox equipment.  Diagram is a 
representation only and not drawn to scale. 
 
W ID T H
 
D o c u T e c h   6 1 x x  
R e p r e s e n t a t io n   o n ly .
D
E
P
T
H
 
Note: The 6100, 6115, 6135 are available with and without a stand to 
support the controller.  If a stand is ordered, it will be positioned to the 
left of the printer, within the service space envelope. If no stand is 
ordered, the controller will be placed on the floor to the left of the 
printer in the service space envelope.  
Note: The dimensions shown below provide the overall service space 
required, including the space to the nearest obstruction.  The 
dimensions are in 
inches
 and are absolute minimums. 
 
 
With stand
Without stand
Configuration 
Width Depth Width Depth 
6100, 6115, 6135 
with interposer, and 
Finisher 
243.0" 114.0”  240.0” 114.0" 
6100, 6115, 6135 
without Interposer, 
with Finisher  
196.0" 114.0” 193.0”  114.0" 
 
Electrical Requirements
 
Printer/Finisher/Binder 
Line Options: 
Single 
Source 
Voltage 208/240 
Amperage 50 
Cycles 60 
Hz 
Receptacle Xerox Part  No. 
600S3779 
Receptacle NEMA Part No. 
14-50R 
Power Cord Xerox Part No. 
98K19950 
117K9940 
Receptacle Diagram
 
 
* D
edicated power outlets required.  Ensure each power cord has a separate 
circuit that cannot be shared with other devices. 
*15 ft. power cord(s) are provided, however, the distance from the equipment 
to the outlet should not exceed 13.1 ft.   
  
 
Electrical Requirements 
Digital Front End (DFE) Controller Platform:
 
Line Options: 
Dedicated 
Voltage 110V 
Amperage 15 
Cycles 60 
Hz 
15 amp Receptacle Xerox Part No. 
20 amp Receptacle Xerox Part No. 
600S3704 
600S3703 
Receptacle NEMA Part No. 
5 - 20R or 5 - 15R 
Receptacle Diagram 
 or 
 
• 
All controller configurations require a 110VAC, 15 Amp 
grounded receptacle for the outlet strip that provides
 receptacles 
for the 
controller and its peripheral devices (monitor, modem, 
CDROM drive, and tape drive) 
• 
Adapters that eliminate the ground connection to the outlet can 
not be used
• 
Xerox provides 15 feet of cabling with Teflon coating (Plenum 
rated), to connect the controller to the Processor/Finisher. 
 
Interposer 
Line Options: 
Dedicated 
Voltage 120 
Amperage 15 
Cycles 60 
Hz 
Receptacle Xerox Part No. 
600S3704 
Receptacle NEMA Part No. 
5 - 15R 
Power Cord Length 
6 feet 
Receptacle Diagram 
 
 
Installation Considerations
 
• 
There should be a minimum of 78 inches (1,981mm) clearance 
from the floor to the nearest overhead obstruction. 
• 
Mobility Assist Device  - The optional mobility assist device 
reduces the installation clearance required to 30 inches 
(760mm) at the processor end of the printer and 15 inches (380 
mm) at the finisher end. 
• 
For proper operation, the printer must be perfectly level. The 
floor must be level within 2 degrees in any direction. On floors 
less than 2 degrees out of level, installation personnel install a 
leveling kit to level the machine. 
• 
If the floor is more than 2 degrees out of level, this condition 
cannot be corrected by the leveling kit. Another suitable location 
must be found for the printer to be installed properly. 
• 
A minimum 50-inch clearance of exclusive operator area must 
be maintained in front of each component.  This space cannot 
be shared. 
• 
A minimum of 36 inches of clearance is required in the back of 
each component for general service clearance.