Xerox 12.7 B 114 User Manual

Page of 22
6.8.2 German users only
Zum Drucken von Etiketten mit Umlauten DRUCKERVORGABEN > DRUCKER-EINSTELLUNG 
> Plot-Etiketten wählen.
Anschließend im Dropdown-Menü für Fonts einen der folgenden Fonts wählen: HP2 Stick Font 
Latin - 1 oder HP2 Stick font Latin - 1 – Proportional.
6.8.3 Large Scaling Factors
Images set to scale beyond the largest installed roll will not scale beyond the largest width unless 
a specific roll is selected, a specific page size is selected, or mismatch mode is set to something 
other than scaling. This is a behavior that has changed from previous releases (prior to 9.0).
For example: The largest roll installed is 36". Scaling is set to 999%. Submit an ARCH E sized 
drawing (Media Size = Any, Mismatch = Scaling). The drawing will not be scaled.
In order for the output to exhibit the desired scaling factor, one of the following conditions must be 
met:
What to do:
Set Mismatch Mode to Substitute 
Request a Media Size of ARCH E via WebPMT, ACT, or the Driver
Request a Media Size 36" Roll via WebPMT, ACT, or the Driver
6.8.4 HPGL Page – End of File
If the files are streamed via any port on the system, these are treated as a single job and no reset 
is done between them.  However, if one uses the LPD protocol to send the files one at a time, the 
effect is that the printer is reset after each job. If the “Reinitialize after EOF” is set to be on, the 
FreeFlow Accxes firmware will reset the printing parameters after each plot file that is received by 
a serial port or a parallel port. To reset the HPGL parameters on the WebPMT, select Printer 
Defaults > Emulations > HPGL.  Click on the box in front of “Reinitialize after EOF”.  Click on the 
“UPDATE PRINTER” button.
6.8.5 Display of Media Usage
The WebPMT Linear Media Usage displays the Media Usage in METERS.  The mechanical 
meters used on the Xerox Wide Format Print System 721p IOTs can be programmed using the 
IOT diagnostics and are determined by which mode (ANSI or ISO) that the IOT is programmed to 
operate in.  The units of measurement may not be the same. 
6.8.6 Default PostScript Page Size
If a PostScript job does not specify a page size (either by using a compatibility operator such as 
“letter”, or “a4”, or by using the setpagedevice operator /PageSize parameter), the page size used 
is the one specified by the Default PostScript Page Size parameter available via the printer user 
interface, or via the WebPMT.  
6.8.7 “Printer has been updated” message
If the user presses the “UPDATE PRINTER” button without actually making changes first, the 
WebPMT will still return a message that the printer was updated.  The WebPMT cannot 
distinguish a page that has been modified from one that has not been modified.  This is because 
of the “stateless” nature of the http protocol and the fact that no events are generated (html) when 
text values are entered or items are selected. When the “UPDATE PRINTER” button is pressed, 
all the data on the form is gathered and sent to the server.  If the data is valid, the printer is 
updated and “The printer was updated successfully.” message is returned.  If inappropriate data is 
Page 14