TM-T88III series 
Specification 
(STANDARD) 
 
3) Errors that are impossible to recover 
Table 3.7.3  Unrecoverable Errors 
Error Description 
ERROR LED Blinking Pattern 
160 ms
 
Recovery 
R/W error in 
memory or 
gate array 
After R/W checking, the 
printer does not work 
correctly. 
 
 
Impossible to recover. 
High voltage 
error 
The power supply 
voltage is extremely 
high.  
 
Impossible to recover. 
Low voltage 
error 
The power supply 
voltage is extremely low. 
 
Impossible to recover. 
CPU 
execution 
error 
The CPU executes an 
incorrect address or I/F 
board is not connected. 
 
Impossible to recover. 
Internal 
circuit 
connection 
error 
Internal circuits are not 
connected correctly. 
 
Approximately 2.56 s 
 
Impossible to recover. 
NOTE:  When any error shown above occurs, turn off the power as soon as possible. 
3.7.2 Printer Operation When an Error Occurs 
The printer executes the following operations when detecting an error. 
  Stops all printer operations for the selected paper section. 
  Goes BUSY (Refer to Section 3.3.3 DIP switches when DIP switch 2-1 is off). 
  Blinks the ERROR LED. 
 
3.7.3 Data Receive Error (only in the serial interface specification) 
If one of the following errors occurs during serial interface communication, the printer prints "?" or 
ignores the data, depending on the setting of DIP switch 1-1. 
 Parity error 
 Framing error 