SATO 408E User Manual

Page of 102
SECTION 3.
CONFIGURATION
PRINTER DIP SWITCH CONFIGURATION
DIP Switch Panels
There are two DIP switches (DSW2 and DSW3) located inside the cover. These
switches can be used to set:
Thermal transfer or direct thermal mode
Label sensor enable/disable
Head check mode
Hex dump mode
Single Job or Multi-Job Receive buffer
Operation mode
In addition, a third DIP switch is located on the RS232 Serial Adapter module and is
used to set the RS232C transmit/receive parameters
Each switch is an eight section toggle switch. The ON position is always to the top. To
set the switches, first power the unit Off, then position the DIP switches. Finally, after
placing the switches in the desired positions, power the printer back on. The switch
settings are read by the printer electronics during the power up sequence. They will
not become effective until the power is cycled.
RS232 Transmit/Receive Setting (located on RS232 I/F Module)
Data Bit Selection (DSW1-1). This switch sets the printer to receive either 7 or 8
bit data bits for each byte transmitted.
Parity Selection (DSW1-2, DSW1-3). These switches select the type of parity
used for error detection.
SATO CL Series “e” Printers
PN 9001074 Rev. B
Page 3-1
DSW1-1
SETTING
Off
8 data bits
On
7 data bits
1
2
3
4
5
6
7
8
ON
OFF
DSW1
DSW1-2
DSW1-3
SETTING
Off
Off
No Parity
Off
On
Even
On
Off
Odd
On
On
Not Used
1
2
3
4
5
6
7
8
ON
OFF
DSW1