Yamaha VL70-m User Manual

Page of 123
108
Symptom
No sound.
Possible Causes
Is the amplifier/mixer power turned on?
Is the amplifier/mixer volume set to an appro-
priate level?
Is the VL70-m volume control set to an appro-
priate level?
Are the VL70-m outputs properly connected to
the amplifier/mixer inputs?
Are the connection cables shorted, open, or
otherwise faulty?
Is the HOST SELECT switch set appropriately
for your system (page 20)?
Is the echo back (or MIDI THRU) function on
your computer or sequencer set properly?
Is the VL70-m MIDI receive channel set
properly (pages 34 and 38)?
Is the PLAY mode Volume parameter set
properly (pages 32 and 38)?
Is the PLAY mode Master Volume parameter
set properly (page 41)?
Is the PLAY mode Expression parameter set
properly (page 38)?
Are the filter and EG attack times set to
unusually long values (page 72)?
Are the high and low note limit parameters in
the “Others” edit mode set to appropriate values
(page 81)?
Is the Voice Level parameter in the “Others”
edit mode set to an appropriate value (page
79)?
Is the Breath Mode parameter set properly
(page 96)?
If a WX-series Wind MIDI Controller is
unplugged from the VL70-m while no breath is
applied to the controller, the breath value can
get “stuck” at “0”, resulting in no sound output.
Symptom
Volume too low.
Possible Causes
Is the PLAY mode Volume parameter set
properly (pages 32 and 38)?
Is the PLAY mode Expression parameter set
properly (page 38)?
Is the PLAY mode Master Volume parameter
set properly (page 41)?
Is the Voice Level parameter in the “Others”
edit mode set to an appropriate value (page
79)?
Are the “Others” edit mode Velocity Depth and
Velocity Offset parameters set to appropriate
values (page 81)?
Symptom
Distorted sound.
Possible Causes
Is the VL70-m connected to a high-sensitivity
microphone or instrument input on your
amplifier or mixer? Try turning the VL70-m
DOWN controls down to avoid overloading the
amplifier/mixer inputs.
Is a distortion-type effect being used (page 94)?
Symptom
Wrong pitch.
Possible Causes
Is the master tune parameter set properly (page
98)?
Is the transpose or system transpose parameter
set properly (pages 33 and 41)?
Is the note shift parameter set properly (page
35)?
Is the “Others” edit mode Detune parameter set
properly (page 79)?
Are inappropriate RPN Fine Tune or RPN
Coarse Tune MIDI message being received
from an external MIDI device?
Symptom
Can only play one note at a time (i.e. no
polyphony).
Possible Causes
The VL70-m is a monophonic tone generator
which is capable of producing only one note at
a time.
Appendix