Yamaha VL70-m User Manual

Page of 123
27
Voice Organization and Sound Module Modes
The VL70-m Sound Module Modes
The VL70-m has two main Sound Module Modes: VOICE and VL-XG. It is
important to understand the difference between these modes because they
determine how the VL70-m responds to MIDI program change and bank num-
bers received from a MIDI keyboard or other controller, and how the internal
effects relate to the individual voices.
The VOICE Mode
In this mode the VL70-m functions as a “standard” tone generator module. The
VOICE mode should be used when the VL70-m is being used alone or with
other non-XG tone generators/synthesizers (see “VL Extension for XG”, page
30).
 Voice Selection
The PRESET 1, PRESET 2, CUSTOM, and INTERNAL voices can be indi-
vidually selected by the VL70-m panel VALUE [-] and [+] buttons, or appropri-
ate MIDI program change numbers and bank numbers received from your
keyboard or controller (see the “Voice Organization” section, above).
 Voice Editing
In the VOICE mode the INTERNAL voices can be individually edited via the
VL70-m panel controls. Each voice has its own edit parameters which can be
stored with the voice are recalled whenever the voice is selected. In fact, the
edited data must be stored with the voice before a new voice is selected other-
wise the edited data will be lost.
 Effects
Each voice has its own effect settings which are recalled whenever the voice is
selected, so that effects become an important part of the individual sound of
each voice. As with edited voice data, edited effect data must be stored with the
voice before a new voice is selected otherwise the edited effects data will be
lost.
 MIDI Output
Normally, MIDI data received at the VL70-m MIDI IN connector is re-transmit-
ted “as is” via the MIDI OUT connector. The Note Filter function described on
page 99 can be used to filter out (i.e. block) note data transmission on specified
channels.