DevNo. (Device Number)
Settings: 001 … 016, all
The Device Number parameter must be set prop-
erly when you want to transmit or receive MIDI
system exclusive data to or from another VL70-m
or other MIDI device (system exclusive data
includes voice parameters, system setup param-
eters, etc). The VL70-m Device number must be
set to the same number as the Device Number of
the external device. Select a device number from
“001” to “016”, or “all” . When “all” is selected,
MIDI system exclusive data can be received on all
device numbers, but transmission occurs via device
number 001.
M.Volum (Master Volume)
Settings: 000 … 127
Sets the VL70-m master volume level. The higher
the value the louder the volume.
RevRtn (Reverb Return)
Settings: 000 … 127
Adjusts the level of the signal returned from the
VL70-m reverb effect stage. The higher the value,
the higher the level of the reverb signal.
ChoRtn (Chorus Return)
Settings: 000 … 127
Adjusts the level of the signal returned from the
VL70-m chorus effect stage. The higher the value,
the higher the level of the chorus signal.
VarRtn (Variation Return)
Settings: 000 … 127
Adjusts the level of the signal returned from the
VL70-m variation effect stage. The higher the
value, the higher the level of the variation signal.
This parameter is not available (“***” will appear
in place of the VarRtn value) when the variation
stage is connected as an “insertion” effect (page
86).
Trans (Transpose)
Settings: -24 … 0 … +24
Transposes the pitch of the entire VL70-m system
(a single setting applies to all voices) down or up
in semitone steps over a 
±
2 octave range. “+00”
corresponds to standard pitch. Each increment
corresponds to a semitone. A setting of “-12”, for
example, transposes the pitch down one octave.