Printronix T5000R User Manual

Page of 102
Advanced Validator Options
57
4.
Press 
 until Defects displays.
5.
Press + or  to scroll through the percentage values: 0% to 
100%. The default is 20%.
6.
Press 
 to select the desired value.
7.
Press 
 and 
 at the same time to lock the 
 key, then press 
PAUSE to take the printer offline.
8.
Press PAUSE again to put the printer online.
Overall Grade
This menu item sets the value used by the validator for pass/fail 
threshold during the analysis of bar codes. Instead of a letter grade, 
numbers are used to allow for more resolution. The numbers can 
be translated to letter grades according to the 4.0 grade table 
below.
Any bar code with a grade below this threshold value will cause the 
printer to display the Overall Grade Fail error message (see “Error 
Messages” on page 86
) and take the appropriate error action. 
Higher values create a stricter pass criterion.
The Overall Grade is determined by taking the lowest grade 
obtained for any of these bar code quality parameters: 
Decodeability, Percent Decode, Defects, Modulation, EC Min, 
Rmin, and Symbol Contrast.
You can set the Overall Grade parameter to a value from 0.5 to 4.0. 
The default is 0.5.
Table 4. Grading Scale for Overall Grade
Letter Grade
Grade Numerical Range
A
3.5 to 4.0
B
2.5 to 3.4
C
1.5 to 2.4
D
0.5 to 1.4
F
0.0 to 0.4