Configuring The Validator
60
2.
If necessary, press 
↓ 
and 
 at the same time to unlock the 
key.
3.
If necessary, press 
 until VALIDATOR displays.
4.
Press 
 until EC Min displays.
5.
Press + or  to scroll through the percentage values: 0% to 
100%. The default is 15%.
6.
Press 
 to select the desired value.
7.
Press 
 and 
 at the same time to lock the 
 key, then press 
PAUSE to take the printer offline.
8.
Press PAUSE again to put the printer online.
Rmin
NOTE: This parameter factors into the Overall Grade (page 57).
This menu item sets the minimum reflectance value used by the 
validator for pass/fail threshold used during the analysis of bar 
codes. A bar code will fail if all the bar reflectance values are above 
the percentage of space reflectance set by this threshold. For 
example, an Rmin setting of 50% requires that at least one bar 
reflectance value fall under the mid point of the reflectance value 
read for the highest space reflectance.
You can set the Rmin parameter to a percentage value from 0% to 
100%. The default is 50%.
1.
Press 
 to take the printer offline and place the printer in 
Menu mode.
2.
If necessary, press 
↓ 
and 
 at the same time to unlock the 
key.
3.
If necessary, press 
 until VALIDATOR displays.
4.
Press 
 until Rmin displays.
5.
Press + or  to scroll through the percentage values: 0% to 
100%. The default is 50%.
6.
Press 
 to select the desired value.
7.
Press 
 and 
 at the same time to lock the 
 key, then press 
PAUSE to take the printer offline.