Connecting a Single ALM2064 Alarm Interface Unit
To connect a single ALM2064 Alarm Interface Unit:
1.
Connect the ALM2064 OUT port to COM 3 on the CM6800-32X6 using the 6-foot (1.8 m) straight data cable supplied with the CM6800.
2.
Set SW2, DIP switches 1-8 to the appropriate positions for the local address (default address setting is 1). Refer to the ALM2064
Alarm Interface Unit Installation/Operation Manual for instructions.
COM 1
2
3
4
5
16
6
32
31
3
VIDEO 
120/230V~
50/60 HZ
25 WATTS
  
1 2 3 4 5 6 7 8
CONTROL
  
T
+
T
-
R
+
R
-
2
  
ALM2064
CONNECT THROUGH
THE "OUT" PORT
COM 3 DEFAULT SETTINGS:
M, RS-485, 19200 BAUD,
1 STOP BIT
NO PARITY, 8 DATA BITS, 
  
STRAIGHT CABLE
(SUPPLIED)  
ALM2064
RJ-45 PIN-OUTS
1  Tx+
2  Tx-   
3
4   
5   
6   
7  Rx-
8  Rx+
CM6800 -32X6 COM 3
RJ-45 PIN-OUTS
1  Rx+
2  Rx-
3  NC
4  NC
5  GROUND
6  NC
7  Tx-
8  Tx+
RS-485
  
010101
Figure 17.  Connecting a Single ALM2064 Alarm Interface Unit
Connecting a Single REL2064 Relay Interface Unit
To connect a single REL2064 Relay Interface Unit:
1.
Connect the REL2064 OUT port to COM 3 on the CM6800-32X6 using the 6-foot (1.8 m) straight data cable supplied with the CM6800.
2.
Set SW2, DIP switches 1-8 to the appropriate positions for the local address (default address setting is 1). Refer to the REL2064
Relay Interface Unit Installation/Operation Manual for instructions.
COM 1
2
3
4
5
16
6
32
31
3
VIDEO 
120/230V~
50/60 HZ
25 WATTS
  
1 2 3 4 5 6 7 8
CONTROL
  
T
+
T
-
R
+
R
-
2
  
REL2064
CONNECT THROUGH
THE "OUT" PORT
STRAIGHT CABLE
(SUPPLIED)
REL2064
RJ-45 PIN-OUTS
1  Tx+
2  Tx-
3   
4   
5   
6   
7  Rx-
8  Rx+
CM6800-32X6 COM 3
RJ-45 PIN-OUTS
1  Rx+
2  Rx-
3  NC
4  NC
5  GROUND
6  NC
7  Tx-
8  Tx+
COM 3 DEFAULT SETTINGS:
M, RS-485, 19200 BAUD,
1 STOP BIT
NO PARITY, 8 DATA BITS,
  
010101
Figure 18.  Connecting a Single REL2064 Relay Interface Unit