Kodak 20R User Manual

Page of 166
Using the System
September 2000
2-5
The system automatically downloads the LUT file to the printer to create a test 
print. When the test print has been sent to the printer, the Scanning 
Processed Print with Densitometer
 status icon on the KODAK LED Printer 
Calibration screen is highlighted.
Obtaining Densities
Obtaining Densities from a File
If the configuration settings include obtaining the density data from a file, the 
Waiting for Density File dialog box appears. Otherwise, go to “Using the 
Densitometer to Read Densities.”  
NOTE: To create a density file, see “Creating a Density File for Use with Calibration” 
1.
Click OK to continue with the calibration process. 
2. Go 
to 
Using the Densitometer to Read Densities
Do the following to scan the neutral (gray) patches on the processed test print into 
the densitometer (refer to your densitometer manual for detailed instructions on 
using the densitometer):
1.
Slide the lever on the densitometer to position 15. Align the edge of the test 
print with the lever on the densitometer. Gently feed the test print through the 
densitometer to scan the patches labeled “even”.
2.  Slide the lever on the densitometer to position 20. Align the edge of the test 
print with the lever on the densitometer. Gently feed the test print through the 
densitometer to scan the patches labeled “odd”.