Bixolon SRP-350 User Manual

Page of 59
 
Rev. 2.01 
- 10 -
SRP-350/352plusA&C
2-2 Operation 
 
2-2-1 Setting the DIP switches 
 
The DIP switches are located on the bottom of the printer. The DIP switches are used to set the printer to perform various 
functions. Follow these when changing DIP switches setting : 
 
1.  Turn the printer power switch off. 
2.  Remove the screw on the bottom of the printer and open the 
bracket. 
3.  Flip the DIP switches using tweezers or another marrow-ended 
tool. Switches are in when up and off when off down in the 
Figure 3-12. 
4.  The new setting takes effect when you turn on the printer. 
 
Note : Always change DIP switch settings only when the 
  printer is turned off. Change made with the power on 
  have no effect and then on again. 
 
     
Figure 2-5 Setting the DIP switches 
 
2-2-2 Setting the DIP switch (RS-232C Serial Interface) 
 
• DIP Switch 1 
SW 
Function 
ON 
OFF 
Default 
1-1 
Auto Line Feed 
Enable 
Disable 
OFF 
1-2 Handshaking 
XON/XOFF 
DTR/DSR 
OFF 
1-3 Data 
Length 
7bits 
8bits 
OFF 
1-4 Parity 
Check 
Yes 
No 
OFF 
1-5 Parity 
Selection 
EVEN 
ODD 
OFF 
1-6 
OFF 
1-7 
ON 
1-8 
Baud Rate Selection (bps) 
Refer to the following table 1 
OFF 
 
• DIP Switch 2 
SW 
Function 
ON 
OFF 
Default 
2-1 Reserved 
OFF 
2-2 
Internal bell control 
Internal bell disable 
Internal bell enable 
OFF 
2-3 Auto 
Cutter 
Disable 
Enable 
OFF 
2-4 
BUSY Condition 
Receive Buffer Full 
* Offline 
* Receive Buffer Full 
OFF 
2-5 
OFF 
2-6 
OFF 
2-7 
Print Density 
Refer to the following table 2 
OFF 
2-8 
Near-End Sensor Status 
Disable 
Enable 
OFF