IBM A40I TYPE 2271 User Manual

Page of 148
Diagnostic error codes 
Refer to the following diagnostic error codes when using the diagnostic tests. See 
In the following index, can represent any number. 
 
Diagnostic Error Code 
FRU/Action 
000-000-XXX 
BIOS Test Passed 
1.   
No action 
000-002-XXX 
BIOS Timeout 
1.   
Flash the system 
2.   
System board 
000-024-XXX 
BIOS Addressing test failure 
1.   
Flash the system 
2.   
System board 
000-025-XXX 
BIOS Checksum Value error 
1.   
Flash the system 
2.   
Boot block 
3.   
System board 
000-026-XXX 
FLASH data error 
1.   
Flash the system 
2.   
Boot block 
3.   
System board 
000-027-XXX 
BIOS Configuration/Setup error 
1.   
Run Setup 
2.   
Flash the system 
3.   
Boot block 
4.   
System board 
000-034-XXX 
BIOS Buffer Allocation failure 
1.   
Reboot the system 
2.   
Flash the system 
3.   
Run memory test 
4.   
System board 
000-035-XXX 
BIOS Reset Condition detected 
1.   
Flash the system 
2.   
System board 
000-036-XXX 
BIOS Register error 
1.   
Flash the system 
2.   
Boot block 
3.   
System board 
000-038-XXX 
BIOS Extension failure 
1.   
Flash the system 
2.   
Adapter card 
3.   
System board 
000-039-XXX 
BIOS DMI data error 
1.   
Flash the system 
2.   
System board 
000-195-XXX 
BIOS Test aborted by user 
1.   
Information 
2.   
Re-start the test, if necessary 
000-196-XXX 
BIOS test halt, error threshold exceeded 
1.   
Press F3 to review the log file 
2.   
Re-start the test to reset the log file 
 
 
Chapter 6. Symptom-to-FRU Index 
39