2.7.5. 
Direct RDRAM* Clock Routing 
Refer to Chapter 4 Clocking for the Intel 820E chipset platform’s Direct RDRAM clock routing 
guidelines. 
2.7.6. 
Direct RDRAM* Design Checklist 
Use the following checklist as a final check to ensure that the motherboard incorporates solid design 
practices. This list is only a reference. For correct operation, all of the design guidelines within this 
document must be followed. 
Table 9. Signal List 
RSL Signals 
High-Speed 
CMOS Signals 
Serial 
CMOS Signal 
Clocks 
• 
DQA[8:0] 
• 
DQB[8:0] 
• 
RQ[7:0] 
• 
CMD 
• 
SCK 
• 
SIO 
• 
CTM 
• 
CTM# 
• 
CFM 
• 
CFM# 
• 
Ground isolation well grounded. 
 
Via to ground every 0.5 inch around edge of isolation island 
 
Via to ground every 0.5 inch between RIMMs 
 
Via to ground every 0.5 inch between signals (from MCH to first RIMM) 
 
Via between every signal within 100 mils of the MCH edge and the connector edge 
 
No unconnected ground floods 
 
All ground isolation at least 10 mils wide. 
 
Ground isolation fills between serpentines 
 
Ground isolation not broken by C-TABs. 
 
Ground isolation connects to the ground pins in the middle of the RIMM connectors. 
 
Ground isolation vias connect on all 4 layers and should not have thermal reliefs. 
 
Ground pins in RIMM connector connect on all 4 layers. 
• 
V
TERM
 layout yields low noise. 
 
Solid V
TERM
 island is on top layer. Do not split this plane. 
 
Ground island (for ground side of V
TERM
 caps) is on top. 
 
Termination resistors connect directly to the V
TERM
 island on the top layer (without vias). 
 
Decoupling V
TERM
 is critical! 
 
Decoupling capacitors connect directly to top-layer V
TERM
 island and top-layer ground island. 
(See the layout example.) 
 
Use at least 2 vias per decoupling capacitor in the top-layer ground island. 
 
Use 2 
×
 100 
µ
F tantalum capacitors to decouple V
TERM
. (Aluminum/electrolytic capacitors are 
too slow!) 
 
High-frequency decoupling capacitors must be spread out across the termination island so that 
all termination resistors are near high-frequency capacitors. 
 
100 
µ
F tantalum capacitors should be at each end of the V
TERM
 island. 
 
100 
µ
F tantalum capacitors must be connected directly to V
TERM
 island. 
 
100 
µ
F tantalum capacitors must have at least 2 vias/cap to ground. 
 
V
TERM
 island should be 50–75 mils wide. 
 
V
TERM
 island should not be broken.