Dynex DX-PS400W2 User Manual

Page of 8
Legal notices
3
O
UTPUT
• Surge: IEC61000-4-5
• ESD: IEC61000-4-2
• Dimensions:
• 5.5 × 3.4 × 5.9 inches  (W × H × L)
• 150 × 86 × 140 mm (W × H × L)
• EMI/RFI: FCC part 15 Class B,EN55022 Class B
• Power Good Delay Time: 100~500mS
• Power Fail Delay Time: >1ms
• Hold-up Time: 16ms Min.
• Line Regulation: ±1% 
• Over Current Protection:
• Increase the output current at the +5V rail gradually to 
30A~48A. The main output should shutdown
• Increase the output current at the +12V1 rail gradually to 
15A~25A. The main output should shutdown
• Increase the output current at the +12V2 rail gradually to 
15A~25A. The main output should shutdown
• Increase the output current at the +3.3V rail gradually to 
30A~50A. The main output should shutdown
• Over Voltage Protection: 
• +5V:7.0V
• +3.3V:4.3V
• +12V:15.6V
• Short Circuit All output to GND
• Hi-Pot Voltage 1500 Vac, Time 2-3 Sec. cut off current 10 mA MAX.
C
ONNECTORS
• Detachable 24 pin to 20 pin ATX power connector
• 6 standard 5 1/4-inch drive connectors
• 1 standard 3 1/2-inch drive connector
• 1 standard SATA drive power connector
• 1 PCI-Express graphic card power connector
• 4 pin Intel P4 style power connector
Legal notices
Limited 1 Year Warranty 
Dynex warrants that for 1 year from date of purchase as stated on your 
receipt, it will replace this product if found to be defective in materials or 
workmanship. If defective, return the item to the store where it was 
purchased before the expiration of the 1 year warranty period, with your 
original receipt, and we will replace it with a then-current equivalent 
Dynex product (or a pro-rated refund at Dynex's option). This warranty is 
available only for the original purchaser of this product. Dynex will not 
be responsible for any incidental or consequential damages or for any 
loss arising in connection with the use or inability to use this product. 
Some states and provinces do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or 
exclusion may not apply to you. For defective products purchased online, 
please contact:
www.dynexproducts.com
Dynex support service at 1-800-305-2204. Dynex, Richfield, 
Minnesota   
Copyright and disclaimer
© 2005 Dynex. DYNEX and the DYNEX logo are trademarks of Best Buy 
Enterprise Services, Inc. Other brands and product names are trademarks 
or registered trademarks of their respective holders. Specifications and 
features are subject to change without notice or obligation.
Voltage
Min. load
Max. load Regulation Ripple 
and Noise
+3.3V
30A
0.5A
±5%
50mV
+5V
28A
0.3A
±5%
50mV
+12V1
14A
1A
± 5%
120mV
+12V2
15A
1A
±5%
120mV
-5V
0.3A
0A
±10%
100mV
-12V
0.3A
0A
±10%
120mV
+5Vsb
2.0A
0A
± 5%
50mV