Usage | Critical Events
•   Shut down power to Stage 1 outlets (any devices that were on 
and connected to Stage 1 power outlets will now lose power).
•   Enter Stage 2 and show the approximate battery-backup time for 
Stage 2. The backup time will count down.
•   The Stage 2 icon will now blink to indicate it is the current stage. 
The Stage 1 icon will change to a hollow circle (e.g., O) to indicate 
it has shut down.
•   If your IR Blaster is set to Stage 2, then an IR signal will be 
blasted right away.
•   Shut down power to Stage 2 outlets.
•   Enter Stage 3 and show the approximate battery-backup time for 
Stage 3. The backup time will count down.
•   The Stage 3 icon will now blink to indicate it is the current stage. 
The Stage 2 icon will change to a hollow circle (e.g., O) to indicate 
it has shut down.
•   If your IR Blaster is set to Stage 3, then an IR signal will be 
blasted right away.
•   Shut down power to Stage 3 outlets.
•   AVU1500 shuts down.
During battery backup, you can do any of the following:
•   Audible Alert: You can press the front-panel “Audible Alert” button 
while the alert is sounding to temporarily mute the alert sound. The 
front-panel display’s “Audible Alert” ON text will blink as a reminder 
that the alert sound is temporarily muted.
•    Stage Time: If override is off, then you can view the estimated 
battery-backup time for any of the three shutdown stages
4
 . Press 
the “Stage Time” button to cycle through each stage and see how 
much estimated battery-backup time each stage has. Stages that 
have already been shut down will show zero time left. Once you stop 
pressing the “Stage Time” button, the system will time-out after a 
few seconds and go back to showing the battery-backup time for the 
current stage.
•   Override: During battery backup, you can change the  
override status.
 
•   If override is on and then you turn it off, your AVU1500 will 
begin its SmartStage shutdown from the beginning. Of course, 
estimated battery-backup times for each stage may be less than 
normal since some of the usable battery supply has already been 
consumed. Also, the “Stage Time” button will become  
usable again.
 
•   If override is off and then you turn it on, your AVU1500 will stop 
all SmartStage shutdown activities and make power available to 
all rear-panel outlets. Of course, any devices that may have been 
shut down before (i.e., lost power) will regain power but may 
not automatically turn on. Also, the “Stage Time” button will be 
disabled and only the battery-backup override time will  
be viewable.
If override is on, then there are no shutdown stages so only the override battery-backup time can be viewed (i.e., 
estimated total battery-backup time for all outlets).