Fujitsu FTR-G1 User Manual
2
FTR-G1 SERIES
Item
FTR-G1
Contact
Arrangement
1 form C
Material
Silver-tin oxide-indium
Contact Path Voltage Drop (initial) Maximum 100 mΩ (at 6 VDC 1A after stabilization)
Rating
25 A at 14VDC (locked motor load)
Maximum Carry Current*1
25 A / 1 hour (25°C, 100% rated coil voltage)
Maximum Switching Current (reference) 35A, 16VDC
Minimum load (reference)*2
1A, 6VDC
Coil
Rated coil power (20°C)
640 mW
Operate coil power (20°C)
237 mW
Operating Ambient Temperature Range –40°C to +85°C (no frost)
Time Values Operate (at nominal voltage) Maximum 10 ms (not including bounce)
Release (at nominal voltage) Maximum 5 ms (not including bounce, no diode)
Life Mechanical
1x10
6
operations minimum
Electrical
1) 100x10
3
operation minimum, 14VDC, 25A inrush power window
motor (1 operation: 1 forward and 1 reverse)
2) 100x10
3
ops. min. 14VDC, 20A inrush door locked motor
Other
Vibration Resistance Misoperation 10-55HZ, 1.5mm double amplitude
Shock Resistance Misoperation 100 m/s
2
minimum (10G)
Endurance 1,000 m/s
2
mimimum (100G)
Insulation Resistance (initial) Max. 100 MΩ @500 VDC
Dielectric Withstanding Voltage (initial) 500 VAC
Weight
Approximately 3.5g
n
SPECIFICATIONS
Model
Nominal
Coil
Voltage
Coil
Resistance
(±10% at
20°C)
Must Operate
Voltage
Must
Release
Voltage
(at 20°C)
Coil
Power at
Nominal
Voltage
FTR-G1CN009W1
9VDC
126
5.4VDC (at 85°C)
0.75VDC
0.64W
6.8VDC (at 85°C)
FTR-G1CN010W1 10VDC
160
6.5VDC (at 85°C)
0.8VDC
0.64W
8.2VDC (at 85°C)
FTR-G1CN012W1 12VDC
225
7.3VDC (at 85°C)
1.0VDC
0.64W
9.2VDC (at 85°C)
n
COIL DATA CHART
FTR-G1 Series
*1 Need to consider the head from PCB when max. current is more than 10A.
*2 Values when switching a resistive load at normal room temperature and humidity and in a clean environment.
The minimum switching load varies with the switching frequency and operating environment.