Delta Electronics VFD-EL User Manual

Page of 209
Chapter 1 Introduction| 
1-6 
Revision August 2008, 2ELE, V1.02
1.2.1 Ambient Conditions 
Install the AC motor drive in an environment with the following conditions: 
Air Temperature: 
-10 ~ +50°C (14 ~ 122°F) for UL & cUL 
-10 ~ +40°C (14 ~ 104°F) for side-by-side mounting 
Relative Humidity:
<90%, no condensation allowed 
Atmosphere 
pressure: 
86 ~ 106 kPa 
Installation Site 
Altitude: 
<1000m 
Operation 
Vibration: 
<20Hz: 9.80 m/s
2
 (1G) max 
20 ~ 50Hz: 5.88 m/s
2
 (0.6G) max 
Temperature: -20°C 
+60°C (-4°F ~ 140°F) 
Relative Humidity:
<90%, no condensation allowed 
Atmosphere 
pressure: 
86 ~ 106 kPa 
Storage 
Transportation 
Vibration: 
<20Hz: 9.80 m/s
2
 (1G) max 
20 ~ 50Hz: 5.88 m/s
2
 (0.6G) max 
Pollution 
Degree 
2: good for a factory type environment. 
 
Minimum Mounting Clearances 
Frame A Mounting Clearances
 
Option 1 (-10 to +50
°C) 
Option 2 (-10 to +40
°C) 
Air flow 
120mm
120mm
5
0
m
m
5
0
m
m
 
120mm
120mm
5
0
m
m
5
0
m
m
 
Air Flow