Delta Electronics VFD-EL User Manual

Page of 209
                                                                                                          Appendix B  Accessories| 
Revision August 2008, 2ELE, V1.02 
B-3
100%
T0
T1
Braking Time
Cycle Time
ED% = T1/T0x100(%)
 
9. 
For safety reasons, install a thermal overload relay between brake unit and brake resistor. 
Together with the magnetic contactor (MC) in the mains supply circuit to the drive it offers 
protection in case of any malfunctioning. The purpose of installing the thermal overload 
relay is to protect the brake resistor against damage due to frequent brake or in case the 
brake unit is continuously on due to unusual high input voltage. Under these 
circumstances the thermal overload relay switches off the power to the drive. Never let 
the thermal overload relay switch off only the brake resistor as this will cause serious 
damage to the AC Motor Drive. 
R/L1
S/L2
T/L3
NFB
MC
  VFD Series
MOTOR
O.L.
U/T1
V/T2
W/T3
+ P
- N
( )
( )
B1
B2
SA
R/L1
S/L2
T/L3
MC
IM
BR
O.L.
Thermal
Overload
Relay or
temperature
switch
Surge
Absorber
Thermal Overload
Relay
Brake
Resistor
Brake
   Unit
+ P
- N
( )
( )
Note1: When using the AC drive with DC reactor, please refer to wiring diagram in the AC drive
            user manual for the wiring of terminal +(P) of Brake unit. 
Note2: 
 wire terminal -(N) to the neutral point of power system.
Do NOT
Temperature