Automatic Voltage Regulators
increase low or decrease high voltage to computer 
safe 110/120 volts. The AVR automatically provides 
battery back-up power if line voltage drops below 90 
volts or exceeds 140 volts.
AVR
INCONSISTENT
UTILITY POWER
CONSISTENT 
SAFE POWER
IN
OUT
CP900D / CP1000D / 
CP1200D / CP1285D / CP1500D
User’s Manual
K01-0000003-00
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the 
unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION!    To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 
contaminants.  (Please see specifications for acceptable temperature and humidity range).
CAUTION!  To reduce the risk of electric shock, do not remove the cover except to service the battery.  No user serviceable parts inside 
except for battery.
CAUTION!  Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION!  UPS must be connected to an AC power outlet with fuse or circuit breaker protection.  Do not plug into an outlet that is not 
grounded.  If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION!  To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 
computer component.
CAUTION!  To reduce the risk of fire, connected only to a circuit provided with 20 amperes maximum branch circuit over current protection in 
accordance with the national Code, ANSI / NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!  CyberPower Systems does not sell products for life support or medical 
applications.    DO  NOT  use  in  any  circumstance  that  would  affect  operation  or  safety  of  any  life  support  equipment  or  with  any  medical 
applications or patient care.
DO  NOT  USE  WITH  OR  NEAR  AQUARIUMS!    To  reduce  the  risk  of  fire  or  electric  shock,  do  not  use  with  or  near  an  aquarium.   
Condensation from the aquarium can cause the unit to short out.
DO NOT USE WITH LASER PRINTERS!  The power demands of these devices will overload and possibly damage the unit.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(1) UPS unit; (1) User’s manual; (1) PowerPanel™ Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 
registration card; (1) Coaxial Cable 
OVERVIEW
The  CP900D  /  CP1000D  /  CP1200D  /  CP1285D  /  CP1500D  provide  automatic  voltage  regulation  for 
inconsistent  utility  power.  The  CP900D  /  CP1000D  /  CP1200D  /  CP1285D  /  CP1500D  features 
890/890/1080/1080/1500 Joules of surge protection, and provide battery backup during power outages.  
The CP900D / CP1000D / CP1200D / CP1285D / CP1500D ensure consistent power to your computer 
system and include software that will automatically save your open files and shutdown your computer 
system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR?
The  CP900D  /  CP1000D  /  CP1200D  /  CP1285D  /  CP1500D  stabilize  inconsistent  utility  power. The  incoming  utility 
power  may  be  damaging  to  important  data  files,  but  with  Automatic  Voltage  Regulation,  the  computer  will  not  experience 
damaging  voltage  levels.    An  Automatic  Voltage  Regulator  automatically  increases  low  or  decreases  high  voltage  to  a  consistent, 
computer safe 110v/120v.  The unit’s powerful sealed lead-acid batteries will provide power only if the incoming voltage drops below 90v or 
increases above 140v.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt.  However, recharging the batteries for at least 16 hours is recommended to insure 
that  the  battery’s  maximum  charge  capacity  is  achieved.   A  loss  of  charge  may  occur  during  shipping  and  storage.    To  recharge  the 
batteries, simply leave the unit plugged into an AC outlet.  The unit will charge in both the ON as well as the OFF position.
2. With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data storage device (Zip drive, Jazz 
drive, Tape drive, etc…) into the battery power supplied outlets.  Plug your peripheral equipment (printer, scanner, speakers) into the full-
time surge protection outlets.  
DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum or other large electrical 
device into the UPS.  The power demands of these devices will overload and possibly damage the unit.
3. To  surge  protect  a  network  connection,  connect  a  network  cable  from  the  wall  jack  outlet  to  the  IN  jack  of  the  UPS. Then  connect  a 
network cable from the OUT jack on the UPS to the network device.
4. Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).  Make sure the wall branch outlet is protected by a 
fuse or circuit breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc…).  
The warranty prohibits the use of extension cords, outlet strips, and surge strips.
5. Press the power switch to turn the unit on.  The power on indicator light will illuminate and the unit will “beep” once.
6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep.  To correct this, turn the UPS off and unplug at 
least one piece of equipment from the battery power supplied outlets.  Wait 10 seconds.  Make sure the circuit breaker is depressed and 
then turn the UPS on.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store your UPS for an extended period, cover it and store with the battery fully charged.  While in storage recharge the battery every 
three months to insure battery life.
DESCRIPTION
1  Power Switch
Can be used as a master on/off switch for equipment connected to the battery power supplied outlets.
2  Power On Indicator
This LED is illuminated when the utility condition is normal and the UPS outlets are providing power, free of surges.
3  Using Battery Indicator
This LED is illuminated when the unit is running in the backup condition.
  4  AVR Indicator
This LED is illuminated when the unit is running in the AVR mode.
  5  Over Load Indicator
This LED is illuminated when the unit is overload.  You will need to reduce the load.
  6  Battery and Surge Protected Outlets
The unit has four battery powered/surge protected outlets for connected equipment and insures temporary 
uninterrupted operation of your equipment during a power failure.
  7  Full-Time Surge Protection Outlets
The unit has four always on surge suppression outlets.
  8  Electrical Wiring Fault Indicator
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.  If 
this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is 
properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet.
  9  Communication Protection Ports
Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet connection.
 10  Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection. 
 11  Serial/USB Ports to PC
The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit.  The USB port will 
communicate with PowerPanel™ Personal Edition and the  DB-9 port is for use with a serial cable and the Microsoft UPS Service.
CAUTION!  Read  and  follow  the  IMPORTANT  SAFETY  INSTRUCTIONS  before  servicing  the  battery.    Service  the  battery  under  the 
supervision of personnel knowledgeable of batteries and their precautions.
CAUTION! Use only the specified type of battery.  See your dealer for replacement batteries.
CAUTION!  The  battery  may  present  a  risk  of  electrical  shock.    Do  not  dispose  of  battery  in  a  fire  as  it  may  explode.  Follow  all  local 
ordinances regarding proper disposal of batteries.  Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as 
required by most state laws.
CAUTION! Do not open or mutilate the batteries.  Released electrolyte is harmful to skin and eyes and may be toxic.
CAUTION! A battery can present a high risk of short circuit current and electrical shock.  Take the following precautions before replacing the 
battery:
1.Remove all watches, rings or other metal objects.
2.Only use tools with insulated handles.
3.Do not lay tools or metal parts on top of battery or any terminals.
4.Wear rubber gloves and boots.
5.Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. 
CONTACT WITH GROUNDED BATTERY
   CAN RESULT IN ELECTRICAL SHOCK!
Model
CP900D
CP1000D
CP1200D
CP1285D
CP1500D
Capacity
900VA / 560W
1000VA / 580W
1200VA / 720W
1285VA / 750W
1500VA / 900W
Input Voltage on Utility
90V to 140V
Input Frequency
60 Hz ± 3 Hz
On-Battery Output Voltage
120Vac ± 5%
Transfer Time
4ms Typical
Max. Load for UPS Outlets
900VA / 560W
1000VA / 580W
1200VA / 720W
1285VA / 750W
1500VA / 900W
Max. Load for Full-Time 
Surge Protection outlets (8 Outlets)
12 Amps
On-Battery Output Wave Form
Simulated Sine Wave Form
Operating Temperature
+ 32°F to 95° F / 0° C to 35° C
Operating Relative Humidity
0 to 95% NON-CONDENSING
Size (L x W x H)
         
                 
13 1/8” x 4” x 9 7/8”
                           
33.3 x 10.0 x 24.9cm
Net Weight
                            22.2 lbs
                                        24.4 lbs
25.6 lbs
Typical Battery Recharge Time
8 hours typical from total discharge
Typical Battery Life
                     3 to 6 years, depending on number of discharge/recharge cycles
Battery Type
                        Spill-proof, Maintenance-free, sealed lead-acid
Safety Approvals
UL1778(UPS), cUL107., FCC/DoC Class B
Model
iMac G4
Desktop PC  
Desktop PC
Desktop PC 
Desktop PC
with LCD Monitor
with 15” Monitor
with 17” Monitor
with 21” Monitor
CP900D
105 minutes
75 minutes
60 minutes
40 minutes
35 minutes
CP1000D
105 minutes
75 minutes
60 minutes
40 minutes
35 minutes
CP1200D
145 minutes
90 minutes
66 minutes
50 minutes
42 minutes
CP1285D
145 minutes
90 minutes
66 minutes
50 minutes
42 minutes
CP1500D
170 minutes
100 minutes
75 minutes
58 minutes
48 minutes
IMPORTANT SAFETY WARNINGS
INSTALLING YOUR UPS SYSTEM
BASIC OPERATION
TROUBLE SHOOTING
TECHNICAL SPECIFICATIONS
  1. Turn off and unplug all connected equipment.
  2. Turn the UPS off and unplug it from the AC power source.
  3. Turn the UPS upside down.
  4. Remove the retaining screw.
  5. Slide the battery compartment cover (front panel) completely off of the unit.
  6. Remove the batteries from the compartment.
  7. Disconnect the battery wires from the batteries.
  8. Install the replacement batteries by connecting the red wire and black wire to the same color 
wires from the battery pack.
  9. Put the batteries back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw. 
11. Recharge the UPS for 8-16 hours to fully charge the battery. 
REPLACING THE BATTERY
REMINDER:  Batteries  are  consider  HAZARDOUS  WASTE  and  must  be  disposed  of  properly.   Almost  any  retailer  that  sells  lead-acid 
batteries collects used batteries for recycling, as required by most state laws.
Additional troubleshooting information can be found at
www.cyberpowersystems.com/support.htm
Problem
Possible Cause
Solution
Full-time surge protection outlets 
stop providing power to equipment. 
Circuit breaker button is projecting 
from the side of the unit.
Circuit breaker has 
tripped due to an 
overload.
Turn the UPS off and unplug at least one piece of equipment.  
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on.
The UPS does not perform 
expected runtime.
Recharge the battery by leaving the UPS plugged in.
Contact CyberPower Systems about replacement batteries at 
tech@cyberpowersystems.com
Battery is slightly worn out.
Battery not fully charged.
The UPS will not turn on.
The on/off switch is designed 
to prevent damage by rapidly 
turning it off and on.
Turn the UPS off.  Wait 10 seconds and then turn the UPS on.
The unit is not connected to an 
AC outlet.
The unit must be connected to a 110/120v 60Hz outlet.
The battery is worn out.
Contact CyberPower Systems about replacement batteries at 
tech@cyberpowersystems.com
Mechanical problem.
Contact CyberPower Systems at 
tech@cyberpowersystems.com
PowerPanel™ Personal Edition 
is inactive (all icons are gray).
The USB cable is not 
connected.
Connect the USB cable to the UPS unit and an open USB port 
on the back of the computer.  You must use the cable that came 
with the unit.
The USB cable is connected 
to the wrong port.
Check the back of the computer for an additional USB port.  
Move the cable to this port.
The unit is not providing 
battery power.
Shutdown your computer and turn the UPS off.  Wait 10 
seconds and turn the UPS back on.  This should reset the unit.
EXPECTED RUNTIME IN MINUTES
(Due to the differences in computer components, the runtime will vary.)
 12  Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.
 13  Outlets Designed for AC Adapters
The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.
Note: Only one of these two ports can be used to communicate with your computer at one time.
Note: To install PowerPanel™ Personal Edition Software the computer will need Microsoft
R
 Internet Explore 5.0 or higher installed.
Note: If using the Serial Port please read the directions to configure the Microsoft
R
 UPS service on our website 
http://www.cyberpowersystems.com/ups_service.asp .  If you need a serial cable please contact CyberPower technical support at 
tech@cyberpowersystems.com
TO REPLACE THE BATTERY