CyberPower CP800AVR / BF800 Leaflet

Page of 2
 
 
 
       
 
 
 
 
CP685AVR / BF685 
CP800AVR / BF800 
User’s Manual   
K01-BF80000
 
IMPORTANT SAFETY WARNINGS 
 
(SAVE THESE INSTRUCTIONS) 
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the 
unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 
CAUTION!  To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive 
contaminants.    (Please see specifications for acceptable temperature and humidity range). 
CAUTION!  To reduce the risk of electric shock, do not remove the cover except to service the battery.    No user serviceable parts inside 
except for battery. 
CAUTION!  Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 
CAUTION!  UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 
grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 
CAUTION!  To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 
computer component. 
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!    CyberPower Systems does not sell products for life support or medical 
applications.  DO NOT use in any circumstance that would affect operation or safety of any life support equipment or with any medical 
applications or patient care. 
DO NOT USE WITH OR NEAR AQUARIUMS!    To reduce the risk of fire or electric shock, do not use with or near an aquarium.   
Condensation from the aquarium can cause the unit to short out. 
DO NOT USE WITH LASER PRINTERS!    The power demands of these devices will overload and possibly damage the unit. 
 
INSTALLING YOUR UPS SYSTEM   
 
 
UNPACKING 
 
Inspect the UPS upon receipt. The box should contain the following: 
(1) UPS unit; (1) User’s manual; (1) PowerPanel™ Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 
registration card; (1) Coaxial Cable 
 
WHAT IS AVR?
 
 
The  CP685AVR / BF685 CP800AVR / BF800 provide complete power protection from utility 
power that is not always consistent.    The CP685AVR / BF685 CP800AVR / BF800 features 
890 Joules of surge protection, and provide long lasting battery backup with a 8AH / 9AH 
batteries for loss of utility power and voltage sags.  The CP685AVR / BF685 CP800AVR / 
BF800 ensure consistent power to your computer system and include software that will 
automatically save your open files and shutdown your computer system during a utility power 
loss. 
 
AUTOMATIC VOLTAGE REGULATOR
 
 
The CP685AVR / BF685 CP800AVR / BF800 stabilize utility power voltage levels that can be inconsistent.    The incoming utility power may 
be damaging to important data files, but with Automatic Voltage Regulation, the computer will only not experience damaging voltage levels.   
An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent, computer safe 110v/120v.   The 
unit’s powerful 8AH / 9AH battery will provide power only if the incoming voltage drops below 90v or increases above 140v. 
HARDWARE INSTALLATION GUIDE 
 
1.  Your new UPS may be used immediately upon receipt.    However, recharging the 
battery for at least 16 hours is recommended to insure that the battery’s maximum 
charge capacity is achieved.    A loss of charge may occur during shipping and 
storage.    To recharge the battery, simply leave the unit plugged into an AC outlet 
and turn on the power switch. 
2.  With the UPS unit off and unplugged, connect your computer, monitor, and any 
externally powered data storage device (Zip drive, Jazz drive, Tape drive, etc…) into the battery power supplied outlets.    Plug your 
peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets.    DO NOT plug a laser printer, paper 
shredder, copier, space heater, vacuum or other large electrical device into the UPS.    The power demands of these devices 
will overload and possibly damage the unit. 
3.  To surge protect a network connection, connect a network cable from the wall jack outlet to the IN jack of the 
UPS. Then connect a network cable from the OUT jack on the UPS to the network device. 
4.  Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).    Make sure the wall branch outlet is 
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc…).   
The warranty prohibits the use of extension cords, outlet strips, and surge strips. 
5.  Press the power switch to turn the unit on.    The power on indicator light will illuminate and the unit will “beep” once. 
6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug 
at least one piece of equipment from the battery power supplied outlets.    Wait 10 seconds.    Make sure the circuit breaker is depressed 
and then turn the UPS on. 
7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
8.  To store your UPS for an extended period, cover it and store with the battery fully charged.    While in storage recharge the battery every 
three months to insure battery life. 
 
BASIC OPERATION 
 
DESCRIPTION 
 
 
Battery and Surge Protected Outlets 
The unit has four battery powered/surge protected outlets for 
connected equipments and ensures temporary uninterrupted 
operation of your equipment during a power failure. 
 
Full-Time Surge Protection Outlets 
The unit has four always on surge suppression outlets. 
 
Power Switch 
Can be used as a master on/off switch for equipment 
connected to the battery power supplied outlets. 
 
Power On Indicator 
This LED is illuminated when the utility condition is normal 
and the UPS outlets are providing power, free of surges. 
 
Electrical Wiring Fault Indicator 
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.   
If this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the 
outlet is properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet. 
 
Communication Protection Ports 
Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet connection. 
 
Circuit Breaker 
Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.     
 
Serial/USB Ports to PC 
The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit.    The UPS 
communicates its status to the PowerPanel™ Personal Edition software.    This interface is also compatible with Power Management 
UPS control provided by Windows
R
 2000 and Windows
R
 XP. 
Note: Only one of these two ports can be used to communicate with your computer at one time.   
Note: To install PowerPanel™ Personal Edition Software the computer will need Microsoft
R
  Internet Explore 5.0 or higher 
installed. 
Note: If using the Serial Port, users need to download Power Panel
R
  software from our website 
http://www.cyberpowersystems.com
 and order the standard serial cable. If you have any questions email CyberPower 
technical support for help. 
tech@cyberpowersystems.com
   
 
Outlets Designed for AC Adapters 
The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 
 
Vertical Use Stand 
The unit can be placed on it’s end in a vertical orientation. 
Note: We recommend you place the unit next to the wall when standing the unit vertically. 
 
Coax/Cable/DSS Surge Protection 
The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver. 
 
REPLACING THE BATTERY 
 
CAUTION!  Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery.    Service the battery under the 
supervision of personnel knowledgeable of batteries and their precautions. 
CAUTION!    Use only the specified type of battery.    See your dealer for replacement batteries. 
CAUTION!  CAUTION!  The battery may present a risk of electrical shock.    Do not dispose of battery in a fire as it may explode. Follow 
all local ordinances regarding proper disposal of batteries.    Almost any retailer that sells lead-acid batteries collects used batteries for 
recycling, as required by most state laws. 
CAUTION!    Do not open or mutilate the batteries.    Released electrolyte is harmful to skin and eyes and may be toxic. 
CAUTION!  A battery can present a high risk of short circuit current and electrical shock.    Take the following precautions before replacing 
the battery: 
1.  Remove all watches, rings or other metal objects. 
2.  Only use tools with insulated handles. 
3.  Do not lay tools or metal parts on top of battery or any terminals. 
4.  Wear rubber gloves and boots. 
5.  Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. CONTACT WITH GROUNDED BATTERY 
CAN RESULT IN ELECTRICAL SHOCK! 
 
TO REPLACE THE BATTERY 
1.  Turn off and unplug all connected equipment. 
2.  Turn the UPS off and unplug it from the AC power source. 
3.  Turn the UPS upside down. 
4.  Remove the 1 retaining screw. 
5.  Slide the battery compartment cover completely off of the unit. 
6.  Remove the battery from the compartment. 
7.  Disconnect the battery wires from the battery. 
8.  Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery. 
9.  Put the battery back into the compartment. 
10.  Slide back the battery compartment cover and tighten the retaining screw. 
11.  Recharge the unit for 4 – 8 hours to fully charge the battery. 
REMINDER:  Batteries are consider HAZARDOUS WASTE and must be disposed of properly.    Almost any retailer that sells lead-acid 
batteries collects used batteries for recycling, as required by most state laws. 
 
 
TROUBLE SHOOTING 
 
Problem 
Possible Cause 
Solution 
Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit. 
Circuit breaker has tripped due to an 
overload. 
Turn the UPS off and unplug at least one piece of equipment.   
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on. 
Battery not fully charged. 
Recharge the battery by leaving the UPS plugged in. 
The UPS does not perform 
expected runtime. 
Battery is slightly worn out. 
Contact CyberPower Systems about replacement batteries at 
tech@cyberpowersystems.com 
The on/off switch is designed to 
prevent damage by rapidly turning it 
off and on. 
Turn the UPS off.    Wait 10 seconds and then turn the UPS on. 
The unit is not connected to an AC 
outlet. 
The unit must be connected to a 110/120v 60Hz outlet. 
The battery is worn out. 
Contact CyberPower Systems about replacement batteries at 
tech@cyberpowersystems.com 
The UPS will not turn on. 
 
Mechanical problem. 
Contact CyberPower Systems at 
tech@cyberpowersystems.com 
The USB / serial cable is not 
connected. 
Connect the USB / serial cable to the UPS unit and an open 
USB / serial port on the back of the computer.    You must use 
the cable that came with the unit. 
The USB / serial cable is connected 
to the wrong port. 
Check the back of the computer for an additional USB / serial 
port.    Move the cable to this port. 
The unit is not providing battery 
power. 
Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the unit. 
PowerPanel™ Personal Edition 
is inactive (all icons are gray). 
The serial cable is not the cable that 
was included with the UPS unit. 
If you are using a serial cable you must use a CyberPower serial 
cable.    If you need this cable please contact technical support.   
tech@cyberpowersystems.com
 
 
Additional troubleshooting information can be found at 
www.cyberpowersystems.com/support.htm 
 
TECHNICAL SPECIFICATIONS 
 
Model 
CP685AVR / BF685 
CP800AVR / BF800 
Capacity 
685VA / 390W 
800VA / 450W 
Input Voltage on Utility 
90V to 140V 
Input Frequency 
57 Hz to 63 Hz 
On-Battery Output Voltage 
120Vac ± 5% 
Transfer Time 
4ms Typical 
Max. Load for UPS Outlets (4 Outlets) 
685VA / 390W 
800VA / 450W 
Max. Load for Full-Time Surge Protection outlets (8 Outlets) 
12 Amps 
On-Battery Output Wave Form 
Simulated Sine Wave Form 
Operating Temperature 
+ 32°F to 95° F / 0° C to 35° C 
Operating Relative Humidity 
0 to 95% NON-CONDENSING 
Size (L x W x H) 
11” x 6 5/8” x 3 1/2” / 28cm x 16.9cm x 8.7cm 
Net Weight 
13.7 lbs 
14.3 lbs 
Typical Battery Recharge Time 
8 hours typical from total discharge 
Typical Battery Life 
3 to 6 years, depending on number of discharge/recharge cycles 
Battery Type 
12V / 8.0AH 
12V / 9.0AH 
Recommended Battery 
Spill-proof, Maintenance-free, sealed lead-acid 
Safety Approvals 
UL1778(UPS), cUL107., FCC/DoC Class B