Figure 15. Cable Management Bar Installation (Uninterrupted Power Fuse Panel Shown)
4.5
Rack Mounting
The
 fuse panel can be mounted in either a 19- or 23-inch (48.26 or 58.42 cm) wide rack. Two
sets
 of mounting brackets, one set for 19-inch racks and one set for 23-inch racks, are provided
with
 the fuse panel. Eight 5/16-inch (7.94 mm) long, thread-forming, Phillips-drive, 8-32 flat-
head
 screws are provided for attaching the mounting brackets to the panel. Four 3/8-inch (9.53
mm)
  long,  Phillips-drive,  12-24  pan-head  screws  (with  #12  flat  washers)  are  provided  for
attaching
 the mounting brackets to the equipment rack.
 
Use
 the following procedure to install the fuse panel in the equipment rack: 
1. Select
 the set of mounting brackets (19- or 23-inch) that correspond to the width of the
equipment
 rack into which the fuse panel will be installed. 
2. Orient
 the mounting brackets as shown in 
.
3. Attach
 the brackets to the sides of the fuse panel chassis using the eight 5/16-inch (7.94
mm)
  flathead  screws  provided.  Tighten  screws  to  15  pound  force-inches  (1.7  Newton
meters)
 of torque to insure grounding. 
4. Place
 the fuse panel in the specified mounting space within the rack.
5. Secure
 the panel to the rack as shown in 
 using the four 3/8-inch (9.525 mm)
long
 pan-head screws and flat washers provided. 
Caution:
 When attaching the cable management bar to the fuse panel, use only the hardware
supplied
 with the cable management bar. Use of any other hardware could cause contact with
internal
 parts of the fuse panel. If parts are missing, please contact ADC.
Note:
  A  fuse  panel  with  the  cable  management  bar  attached  may  exceed  the  12-inch
(3.05 mm)
 overall depth objective described in GR-63 CORE, 02-14.
Caution:
 When attaching the mounting brackets to the fuse panel, use only the 5/16-inch (7.94
mm)
 long, black chromate finish, thread forming, flathead screws provided with the panel. Use
of
 any other hardware could cause contact with internal parts of the panel. If parts are missing,
contact
 ADC to order replacement parts.
16387-B
CABLE
MANAGEMENT
BAR
ATTACH TO
EITHER SET
OF 3 HOLES
MOUNTING BRACKET
INSTALLED FOR 
19-IN. (48.26 CM)
RACK MOUNTING