3. Operating Precautions
 
DANGER
 
• 
Immediately shut the UPS off if it malfunctions, or if an unusual odor or noise is observed. Failure to 
do so may result in a fire. 
• 
To avoid electric shock, do not open the cover of the UPS. 
 
CAUTION
 
• 
Risk of electric shock, do not remove cover, No user serviceable part inside. Refer serviving to qualified 
personnel. 
• 
The space around the UPS must be well ventilated. Otherwise, gas produced by battery charging 
could result in rupture or explosion of the case. 
• 
Before starting the UPS, make sure that the load side is safe. Be sure to refer to the instruction manual 
while operating the UPS. The operating state of the UPS, as determined by the INV. ON/STAND BY switch 
and the MAIN breaker, is indicated by the LEDs as shown the table below. 
• 
The following table shows the UPS states resulting from operation of the MAIN MCCB and INV ON/STAND 
BY switches. Check the indicators before and after operating. Do not touch the MAIN MCCB and INV 
ON/STAND BY switches unless necessary. 
If power is supplied incorrectly, an electric shock or bodily 
injury could result. 
 
 
 
 
 
 
• 
Avoid inserting sharp objects or fingers into the fan. Doing so may result in bodily injury. 
• 
Do not touch the UPS, including the cables, if you hear thunder nearby. There is danger of electric shock 
from a lightning strike. 
 
PROHIBITED
 
• 
Never use the UPS for the following types of loads:
 
a.  Medical instruments used for life support. 
b.  Control units for trains or elevators, failure of which could cause bodily injury. 
c.  Computer systems upon which social or public infrastructure depends. 
d.  Devices which serve applications related to the above. 
Contact your sales representative if you need to use the UPS in an application like the above. Special 
equipment, such as redundant devices or an emergency generator must be incorporated when operating, 
maintaining and controlling systems in which a UPS is used with loads affecting life-support or public 
infrastructure-dependent applications.
 
• 
This UPS must be installed, operated and maintained by technically qualified personnel in an industrial 
environment. This UPS should not be used in the other environment, for example, a general home 
environment where  a  technically qualified personnel is not in. 
• 
Do not smoke or use an open flame near the UPS, as it could cause the UPS to explode or rupture, resulting 
in injury or fire. 
• 
Do not place containers of liquid, such as a flower vase, on the UPS. If the container was to spill, the liquid 
could cause a short circuit, resulting in sparks or fire inside the UPS. 
• 
Do not sit, step or lean on the UPS, as bodily injury could result if the UPS was to fall. 
• 
Repairs and modifications to the UPS prohibited 
All repairs and modifications to the UPS are prohibited. The UPS contains high voltage and no user 
serviceable parts. Opening the cover, exchanging the battery, parts exchange, and repair can result in 
electric shock and damage to the UPS when performed by anyone other than qualified service personnel. All 
such repairs and modifications will void the warranty. 
 
 
UPS Status
 
Power Output Status
 
MAIN MCCB  INV ON/STAND BY 
OUTPUT  
LEDs
 
OFF STAND 
BY 
Stopped
 
INPUT (off-green), 
 
OUTPUT 
(off-green)
 
ON STAND 
BY 
Stopped
 
INPUT 
(on-green),  
OUTPUT 
(off-green)
 
OFF 
ON 
Power supplied from inverter  INPUT 
(blinking-green), 
OUTPUT
 (on-green)
 
ON 
ON 
Power supplied from inverter  INPUT 
(on-green),  
OUTPUT 
(on-green)