Siemens 440 User Manual

Page of 78
6  Commissioning 
Issue 10/06 
 
MICROMASTER 440 
48 
Operating Instructions (Compact) 
6.4.16 V/f 
control 
 
P1300 =... 
 
Control mode 
The control type is selected using this parameter. For the "V/f characteristic" control type, 
the ratio between the frequency inverter output voltage and the frequency inverter output 
frequency is defined. 
 0  V/f with linear 
 1  V/f with FCC 
  2  V/f with parabolic characteristic 
  3  V/f with programmable characteristic (
→ P1320 – P1325) 
 
P1310 =... 
 
Continuous boost
 (entered in %) 
Voltage boost as a % relative to P0305 (rated motor current) and P0350 (stator resistance). 
P1310 is valid for all V/f versions (refer to P1300). At low output frequencies, the effective 
resistance values of the winding can no longer be neglected in order to maintain the motor 
flux.  
 
f
Linear V/f
OFF
ON
t
t
⏐f⏐
P1310 active
t
0
1
Validity range
Vmax
Vn
(P0304)
V
ConBoost,100
0
fn
(P0310)
f max
(P1082)
V
f
Boost,end
(P1316)
Boost
Ou
tpu
t v
olt
ag
e
actual V
No
rm
al 
V/
f
(P
13
00
 =
 0
)
V
ConBoost,50
Boost voltage
 
 
P1311 =... 
 
Acceleration boost 
(entered in %) 
Voltage boost for accelerating/braking as a % relative to P0305 and P0350. P1311 only 
results in a voltage boost when ramping-up/ramp-down and generates an additional torque 
for accelerating/braking. Contrary to parameter P1312, that is only active for the 1
st
 
acceleration operation after the ON command, P1311 is effective each time that the drive 
accelerates or brakes.  
 
Vmax
Vn
(P0304)
V
AccBoost,100
0
fn
(P0310)
fmax
(P1082)
f
V
f
Boost,end
(P1316)
V
AccBoost,50
Boost
U/
f n
orm
al
(P
13
00
 = 
0)
V ist
Au
sg
an
gs
sp
an
nu
ng
OFF
ON
t
t
⏐f⏐
P1311 aktiv
t
0
1
Boost-Spannung
Gültigkeitsbereich
0
50.00 %
0.0 %