2  Electrical Installation 
Issue 10/06 
 
MICROMASTER 440 
Operating Instructions (Compact) 
Input voltage range 
3 AC 200 V – 240 V. ± 10 % 
(Unfiltered) 
Order No. 
6SE6440-  2UC11
-2AA1
 
2UC12
-5AA1 
2UC13
-7AA1 
2UC15
-5AA1 
2UC17
-5AA1 
2UC21
-1BA1 
2UC21
-5BA1 
2UC22
-2BA1 
2UC23
-0CA1 
Frame Size 
 
A B C 
[kW] 
0,12 0,25 0,37 0,55 
0,75 1,1  1,5  2,2  3,0 
Output Rating(CT) 
[hp] 
0,16 0,33 0,5 0,75 1,0  1,5  2,0  3,0  4,0 
Output Power 
[kVA] 
0,4 0,7 1,0 1,3 1,7 2,4 3,2 4,6 6,0 
CT-Input Current 1) 
[A] 
1,1 1,9 2,7 3,6 4,7 6,4 8,3 11,7 15,6 
CT-Output Current 
[A] 
0,9 1,7 2,3 3,0 3,9 5,5 7,4 10,4 13,6 
Fuse [A] 
10 10 10 16 16 20 20 25 25 
Recommended 3NA 
3803 3803 3803 3805 3805 3807 3807 3810 3810 
For UL specified 
 
* * * * * * * * * 
[mm
2
1,0 1,0 1,0 1,5 1,5 2,5 2,5 2,5 4,0 
Input Cable, min. 
[AWG] 
18 18 18 16 16 14 14 14 12 
[mm
2
2,5 2,5 2,5 2,5 2,5 6,0 6,0 6,0 10,0 
Input Cable, max. 
[AWG] 
14 14 14 14 14 10 10 10  8 
[mm
2
1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,5 
Output Cable, min. 
[AWG] 
18 18 18 18 18 18 18 18 16 
[mm
2
2,5 2,5 2,5 2,5 2,5 6,0 6,0 6,0 10,0 
Output Cable, max. 
[AWG] 
14 14 14 14 14 10 10 10  8 
[kg] 
1,3 1,3 1,3 1,3 1,3 3,3 3,3 3,3 5,5 
Weight 
[lbs] 
2,9 2,9 2,9 2,9 2,9 7,3 7,3 7,3 12,1 
[Nm] 
1,1 1,5 2,25 
Tightening torques 
for power terminals 
[lbf.in] 
(10) (13,3) (20) 
 
Order No. 
6SE6440-  2UC24-
0CA1
 
2UC25-
5CA1 
2UC27-
5DA1 
2UC31-
1DA1 
2UC31-
5DA1 
2UC31-
8EA1 
2UC32-
2EA1 
2UC33-
0FA1 
2UC33-
7FA1 
2UC34-
5FA1 
Frame Size 
 
C D E F 
[kW] 
4,0 5,5 7,5 11,0 
15,0 18,5 22,0 30,0 37,0 45,0 
Output Rating(CT) 
[hp] 
5,0  7,5  10,0 15,0 20,0 25,0 30,0 40,0 50,0 60,0 
Output Power 
[kVA] 
7,7  9,6  12,3 18,4 23,7 29,8 35,1 45,6 57,0 67,5 
CT-Input Current 1) 
[A] 
19,7 26,5 34,2 38,0 50,0 62,0 71,0 96,0 114,0 135,0 
CT-Output Current 
[A] 
17,5 22,0 28,0 42,0 54,0 68,0 80,0 104,0 
130,0 154,0 
VT-Input Current 1) 
[A] 
28,3 34,2 38,0 50,0 62,0 71,0 96,0 114,0 
135,0 164,0 
VT-Output Current 
[A] 
22,0 28,0 42,0 54,0 68,0 80,0 104,0 
130,0 
154,0  - 
Fuse  
[A] 
32 35 50 80 80 100 125 
200 
200 250 
Recommended 3NA 
3812 3814 3820 3824 3824 3830 3832 3140 3142 3144 
For UL specified 
3NE 
* * 
1817-0 1820-0 1820-0 1021-0 1022-0 
1225-0 
1225-0 
1227-0
[mm
2
4,0  4,0  10,0 16,0 16,0 25,0 25,0 70,0 70,0 95,0 
Input Cable, min. 
[AWG] 
12 12 8 6 6 3 3 2/0 
2/0 
3/0 
[mm
2
10,0 10,0 35,0 35,0 35,0 35,0 35,0 150,0 
150,0 150,0 
Input Cable, max. 
[AWG] 
8 8 2 2 2 2 2 
300 
300 
300 
[mm
2
4,0  4,0  10,0 16,0 16,0 25,0 25,0 50,0 70,0 95,0 
Output Cable, min. 
[AWG] 
12 12 8 6 6 3 3 1/0 
2/0 
3/0 
[mm
2
10,0 10,0 35,0 35,0 35,0 35,0 35,0 150,0 
150,0 150,0 
Output Cable, max 
[AWG] 
8 8 2 2 2 2 2 
300 
300 
300 
[kg] 
5,5  5,5  17,0 16,0 16,0 20,0 20,0 55,0 55,0 55,0 
Weight 
[lbs] 
12,1 12,1 37,0 35,0 35,0 44,0 44,0 121,0 
121,0 121,0 
[Nm] 
2,25 10 
50 
Tightening torques 
for power terminals 
[lbf.in] 
(20) (89) 
(445) 
1)  Secondary conditions:  Input current at the rated operating point - applies for the short-circuit voltage of the line 
supply V
k
  = 2 %  referred to the rated drive converter power and a rated line supply voltage 
of 240 V without line commutating reactor.  
*  UL listed fuses such as Class NON from Bussmann are required for use in America