SPECIfICATIONS
Internal Battery Type
Maintenance-free AGM Lead-acid
Nominal Voltage
12 Volt DC
Capacity
18 Ah
DC Power Outlet
15A
Built-in Light Bulb (Replaceable)
2.5w/12v DC
Jumper Cables
Heavy Duty 24 Inch
Dimensions (H X W X D)
12 H X 11.5 X 10.5 Inches
Product Weight
24.5 Lbs.
AC POWER SPECIfICATIONS
Maximum Continuous Power ........................................................................ 400 Watts
Surge Capacity (Output Wattage) ................................................................. 800 Watts
No Load Current Draw ................................................................................. <0.4 Amps
Wave Form .....................................................................................Modified Sine Wave
Input Voltage Range ............................................................................ 10.5 – 15.5V DC
AC Outlets .................................................................Two, 110V AC 3-Prong grounded
STORAgE AND MAINTENANCE 
Charge the PP-18400CI internal battery before first use and after every use thereafter. 
The internal battery will gradually self-discharge (lose power) over time, especially in 
warm environments. Leaving the battery in a discharged state may result in permanent 
battery damage. To ensure satisfactory performance and avoid permanent damage, 
charge the internal battery every 2 to 3 months. The PP-18400CI may be left permanently 
connected to the AC electrical wall outlet. Store in a cool dry place.