8. Accessoires
© STÖBER plc 1998
05.02.01
36
8.2  Clear text Display Module (Opm2) in IP55 housing
see chap. 4.1.
This section only applies for users who intend using the optional Clear Text Display module (OPm2) to
control the operation of the CombiDrive
®
.
The OPm2 module provides a multi-language user-friendly interface to the CombiDrive
®
. The display is menu-
driven and provides information in simple text form. It also includes built-in context-sensitive Help screens.
As well as enabling direct control of the motor, the OPm2 extends the functionality of the CombiDrive
®
by
providing access to a comprehensive range of adjustable parameters. Setting these parameters will allow you
to customise the operation of the CombiDrive
®
to meet almost any application requirement.
1
Pressing this button while the motor is stopped causes it to start and run at the
preset jog frequency. The motor
 stops as soon as the button is released. Pressing
this button while the motor is running has no effect. Disabled if P007 or 123 = 0.
2
Green indicates that the motor is running.
Flashing green indicates that the motor is ramping up or down.
Red indicates that the motor is stationary.
Flashing red indicates a fault condition.
3
Press to start the inverter. Disabled if P007 or P121 = 0.
4
Press to stop the inverter.
5
Changes the display to show the menu options. Pressing and holding this button
down and then pressing the 
 button causes the Help screen to be displayed.
6
Press to change the direction of rotation of the motor. REVERSE is
indicated by a minus sign (values <100) or a flashing decimal point
(values > 100). Disabled if P007 or P122 = 0.
7
Press to INCREASE frequency. Used to change parameter numbers
or values to higher settings during the parameterisation procedure.
Disabled if P124 = 0.
9
Press to access parameters. Disabled if P051 - P053 = 14 when using
digital inputs.
JOG
Button
RUN / STOP
Inducator
2
RUN
Button
3
STOP
Button
4
MENU
Button
4
LCD
Screen
FORWARD / REVERSE
Button
6
UP / INCREASE
Frequency
7
DOWN / DECREASE
Frequency
8
Parameterisation
Button
9