Panasonic MDDDT3530P User Manual

Page of 133
- 66 -
Maintenance  and  Inspections
Å
E
Routine  maintenance  and  inspections  are  essential  for  proper  and  satisfactory  op-
eration  of  the  amplifier  and  motor.
Notes  to  Maintenance/Inspections  Personnel
1)Power-on/off operations should be done by the operators themselves.
2)For a while after power off, the internal circuits is kept charged at higher voltage. Inspections should
be done a while (about 10 minutes), after the power is turned off and the LED lamp on the panel is
extinguished.
3)Do not take insulation resistance measures because the amplifier gets damaged.
Inspection  Items  and  cycles
Normal  (correct)  operating  conditions:
Ambient temperature: 30 °C (annual average) Load factor: max. 80%
Operating hours: max. 20 hours per day
Daily  and  periodical  inspections  should  be  done  per  the  following  instructions.
< N o t e s >
If  the  actual  operating  conditions  differ  from  things  mentioned  above,  the  inspection
cycles  may  change  accordingly.
T y p e
C y c l e s
Daily
Every  year
Inspection items
• Ambient temperature, humidity, dust, particles, foreign matters, etc.
• Abnormal sound and vibration
• Main circuit voltage
• Odor
• Lint or other foreign matters in the ventilation openings
• Cleanliness of the operation board
• Damaged circuits
• Loosened connections and improper pin positions
• Foreign matters caught in the machine (motor load)
• Loosened screws
• Signs of overheat
Daily
i n s p e c t i o n
Periodical
i n s p e c t i o n