Panasonic MDDDT5540 User Manual

Page of 133
- 25 -
List  of  Available  Components
CN  I/F  Connector  (For  Controller)
Wiring  Instructions
Place the peripheral devices such as the
controller max. 3 m away from the amplifier.
• CN I/F Connector Specifications
• The CN I/F pins assignment is shown in "Optional Parts" in Appendix.
Separate these wiring min. 30 cm from the main
circuit wires.  Don't  lay  these wires in the same
duct of  the mains or bundle with them.
The control power (VDC) between COM+ and COM- should
be supplied by the customer (recommended voltage:
+12VDC to +24VDC).
Do not apply power higher than 24V or 50mA to control
signal output terminal.
If you directly activate a relay using the control
signal,install a diode in parallel to the relay as
shown in the left figure. Without a diode or with
it  but  placed  in  the  opposite  direction,  the
amplifier will be damaged.
Use a shielded twist-paired type for the  wiring
of pulse input, encoder signal output, etc.
The  Frame  Ground  (FG)  is  connected  to
an  earth  terminal  in  the  amplifier.
Preparations 
and 
Adjustments
MSDS
MOTOR
CN
SIG
CN
CN
POWER
CN
I/F
ALARM
POWER
GAIN
RS232C
COM+
GND
1
CN I/F
COM-
FG
V
DC
2
Controller
max. 3 m
min. 30 cm
Power
supply
Motor
Receptacle  on  the
amplifier  side
1 0 2 2 6 - 5 2 A 2 J L
Connector  to  controller  side
P a r t   d e s c r i p t i o n
Solder  type  plug  (Soldering  type)
Connector  cover
Part  No.
1 0 1 2 6 - 3 0 0 0 V E
1 0 3 2 6 - 5 2 A 0 - 0 0 8
Manufacturer
Sumitomo
three  M