Panasonic A4P Series User Manual

Page of 232
41
[Preparation]
Preparation
Wiring to the Connector, CN X5 (Connection to Host Controller)
• Tips on wiring
Controller 
3m
or shorter
30cm or longer
COM+
GND
1
CN X5
COM–
FG
V
DC
Power
supply
Motor
2
Peripheral apparatus such as host controller should be located 
within 3m.
Separate the main circuit at least 30cm away.
Don't pass them in the same duct, nor bind them together.
Power supply for control signals (V
CC
) between COM+ and COM– (V
DC
should be prepared by customer.
Use shield twisted pair for the wiring of encoder signal  output.
Don't apply more than 24V to the control signal output terminals, nor run 
50mA or more to them.
When the relay is directly driven by the control output signals, install  a 
diode  in parallel with a relay, and in the direction as the Fig. shows. The  
driver  might be damaged without a diode installment, or by reverse 
direction.
Frame ground (FG) is connected to the earth terminal inside of the 
driver.
• For detailed information, refer to P.42 to 47.
 • Specifications of the Connector, CN X5
<Note>
For details, refer to P.185, "Options" of Supplement.
<Remarks>
 • Tightening torque of the screws for connector (CN X5)  for the connection to the host to be 0.3 to 0.35N
m.
Larger tightening torque than these may damage the connector at the driver side.
Connector at driver side
52986-3679
Part name
Connecter (soldering type)
Connector cover 
Connecter (soldering type)
Connector cover 
Part No.
54306-3611          or       
54306-3619 (lead-free)
54331-0361
10136-3000VE
10336-52A0-008
Connecter to be prepared by customer
Manufacturer
Molex Inc.
Sumitomo 3M
or