16    Chapter 1  Uninterruptable Power Supply (UPS) Overview
 
P0607274   02
The UPS device is supported in all markets (110~120V and 220~240V power standards). All 
BCMs using version 3.5 software or higher can use the UPS device.
BCM and UPS power and control connections
The UPS device operates in parallel with the BCM 200, 400, and 1000. The BCM obtains power 
through the UPS. The UPS obtains power from a conventional AC power source. 
The UPS meets BCM power delivery requirements for 110~120 and 220~240 Volt standards. The 
BCM operational power usage range (shown in the following table) is compatible with the UPS 
operating range. 
The serial connection between the BCM and UPS provides power monitoring and control 
capability. The UPS service uses standard RS232 serial protocol. Figure 2 shows the physical 
BCM connections and OAM topology. 
Figure 2   UPS/BCM power connections and topology
BCM Input Power Source
110 ~ 120 Volt power standards
220 ~ 240 Volt power standards
Minimum (VAC)
Maximum (VAC)
Minimum (VAC)
Maximum (VAC)
90.0
130.0
220.0
265.0
COM port supports a DB9 serial connection 
to a UPS for power monitoring
Unified Manager 
Workstation provides UPS 
configuration, service 
activation and OAM 
monitoring applications
Local Area 
Network
UPS device
Plug BCM power 
cord into UPS
Plug UPS into AC 
power source
CTM 4
1
Aux
2
3
4
DSM 16+
1
2
3
4
1
2
3
4
S tat us
Pow er