3.4 Connecting Power to the System 
A fully loaded RamSan-500 requires approximately 250 watts of power. It 
contains redundant power supplies that are hot-swappable. Using the AC 
power cords provided, connect each power module to a power source. 
Install the socket outlet in an easily accessible location near the 
equipment. 
 
 
Figure 5 – RamSan-500 Power Supply 
The power supply includes the following button and indicators: 
3.4.1
3.4.1
3.4.1
3.4.1 Power 
Power 
Power 
Power S
S
S
Switches
witches
witches
witches    
Each power module has an individual on/off switch and power indicator 
light. 
W
ARNING
A
 HARD
-
SHUTDOWN WILL CAUSE DATA LOSS AND SHOULD ONLY BE USED WHEN 
YOU ARE UNABLE TO PERFORM A MANUAL SHUTDOWN AND BACK UP ALL DATA TO THE 
F
LASH MODULES OR EXTERNAL STORAGE
3.4.2
3.4.2
3.4.2
3.4.2 AC 
AC 
AC 
AC Voltage I
Voltage I
Voltage I
Voltage Indicator 
ndicator 
ndicator 
ndicator L
L
L
Light
ight
ight
ight    
When the power supply is connected to AC power and is operating 
properly, the indicator light attached to each power supply is green. If 
the green light is not on, either the power supply is disconnected from 
an AC power source or the power supply has failed. Check the power 
cable to determine if power has been lost to the supply or the module 
has failed. The front panel display or Web monitor may provide 
additional information regarding the problem. 
Power Supplies