Minuteman UPS ED6200T User Manual

Page of 23
 
4
2 Product 
Introduction 
 
2.1. 
System Overview 
 
This On-Line UPS protects computers, servers, internetworking, and 
telecommunications equipment from blackouts, brownouts, overvoltages, and 
surges. This On-Line UPS converts the input AC to DC and then back to a 
True Sine Wave AC output. The True Sine Wave output is regulated within 
2% of the nominal output voltage. The Power Factor Correction (PFC) 
circuitry corrects the input power factor to within 98% of unity and blocks the 
load generated harmonic distortion from getting back on the input AC line. 
This On-Line UPS provides a continuous true sine wave output with zero 
transfer time and great regulation to protect your mission critical equipment. 
The UPS will quietly and confidently protect your system from power 
anomalies. 
 
2.2. 
General Characteristics 
 
2.2.1  True On-Line architecture continuously supplies your critical equipment with 
a stable, regulated, transient-free, pure sine wave AC Output Power. 
 
2.2.2  The multi-functional LCD/LED panel will display various states of the UPS. 
The LED display will show the UPS working status, Utility Status and UPS 
Abnormal status. The LCD display will show the Input/Output voltage, 
frequency, load status, internal temperature, and faults. 
 
2.2.3  The digital control circuit enhances the ability of the UPS for remote control 
and monitoring. 
 
2.2.4  These UPS systems can be used in a Parallel Redundant application. To 
operate these UPS systems in the Parallel Redundant mode requires the 
Parallel Redundant kit. Contact your local distributor for more information 
concerning the Parallel Redundant operation. 
 
2.2.5  Maintenance Bypass Switch — which reduces down time for maintenance. 
 
2.2.6  The DC-start function allows the start-up of UPS when there is no utility 
power available. 
 
2.2.7  This UPS system has the Independent Battery Bypass function. The 
Independent Battery Bypass function allows the UPS system to provide a 
stable, regulated, transient-free pure sine wave AC output power even 
when the batteries are weak or dead. 
 
2.2.8  The battery management circuit analyses the battery discharging status to 
adjust the battery cut-off point and extend the life of batteries. 
 
5
 
2.2.9 The 
temperature-controlled 
fans 
will extend the life of the fans and reduce 
the annoying noise caused by fans. 
 
2.3. 
Symbols on the LCD Display Panel 
 
Item Symbol 
Description 
LINE 
Utility or Bypass Source 
2  
 
 
Battery Low 
 
 
 
Battery Abnormal 
 
 
 
Output Overload 
 
 
UPS working in specified mode 
 
 
 
A Blackout Transfer occurred in UPS Output 
 
 
Bypass Input Abnormal, UPS fails to transfer 
to Bypass, Bypass Abnormal at ECO mode 
8  
 
 
Utility Input Abnormal 
OFF 
UPS Shutoff 
10 
BPS 
Bypass Mode 
11 
LINE    OFF 
UPS Abnormal Lock 
12 
 
 
 
 
UPS Flow Chart 
13 
 
 
 
 
4 Digits Measurement Display 
14 
 
 
 
Indicate the item desired to be measured