Texas Memory Systems RamSan-300/320 User Manual

Page of 90
 
 
 
6.4.2  Via Text Management 
Linking Fibre Channel Controllers 
•  From the Telnet Main Menu, select “LUN Setup” 
•  Select “Link/unlink fibre channel controller(s) to/from 
LUN(s)” 
 
 
Figure 6-8: Link LUNs Screen 
The Link LUNs screen displays the currently selected controller and 
port above the menu.  Figure 6-8: Link LUNs Screen displays the 
selected controller as 2-A, which is Controller 2 Port A. 
 
•  To change the selected controller select “Select different 
controller”.  This displays a list of controllers.  Select one and 
press [ENTER]. 
•  To change the port, select “Select different channel on 
controller”.  This displays a list of channels.  Select one and 
press [ENTER]. 
 
In addition, the “Link/Unlink LUN(s)” screen indicates the number 
of LUNs currently linked to the selected controller. 
 
•  To link a LUN to the selected controller, select “Link LUN(s) to 
selected controller”.   
•  From the sub-menu that lists all LUN numbers not already 
linked to another FC port, select a LUN number and press 
[ENTER].  
 
If all LUNs are already linked to ports, then the system displays an 
error message.  
 
•  Select “Exit to the LUN configuration menu” 
•  To save the changes once you have completed all LUN 
configuration, select “Save changes and exit” 
 
To ensure that your changes were successful, see Section 6.3  - 
RamSan-300/320 User’s Manual 
 