Appendix E – SNMP Trap 
Definitions 
 
 
The following list provides detailed information about the SNMP v2 notifications 
(traps) that the RamSan 320/325 generates because of various system events.  Each 
trap contains a timestamp, trap OID, brief message, and sometimes a relevant 
system state variable.  The system sends traps to each IP address found in the SNMP 
trap list (configurable through the web and Telnet monitoring tools).  Trap OIDs and 
definitions are located in the MIB file, which can be obtained through the web 
monitor. 
 
 
Name power-on-notif 
Description  
System has turned on 
Includes 
Message 
System Type 
 
 
 
Name power-off-notif 
Description  
A shutdown sequence has been initiated 
Includes 
Message 
 
 
 
RamSan-300/320/325 User’s Manual 
 