Texas Memory Systems 320 User Manual

Page of 122
 
 
 
Status   
The following status levels are possible: 
GOOD”  
This is normal operation. 
 
“WARNING”  
Indicates that the RamSan 
has detected a system 
warning.  Warning 
statements scroll across 
the front panel display. 
 
Possible warning 
examples: 
•  Pwr supply # removed 
•  AC lost at one or both 
power supplies 
•  One or both batteries 
are low 
•  Temperature warning 
•  One disk removed 
 
ERROR”  
Indicates that the RamSan 
has detected a system 
failure.  Error statements 
scroll across the front panel 
display. 
 
Possible failure examples: 
•  Fan failure 
•  Power supply failed 
•  System overheated 
•  More than one disk 
removed or failed. 
 
System Status: 
GOOD 
System Status: 
WARNING
Warnings: Fans slow 
System Status: 
ERROR 
Errors: Disk # Failed 
 
In the case of either system warnings or failures, the front panel 
display alternates between displaying status information and 
warning or failure messages every 10 seconds. 
 
RamSan-300/320/325 User’s Manual 
 
- 40 -