Tripp Lite SU6000RT3U User Manual

Page of 7
 
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model #: SU6000RT3U
SmartOnline 6kVA On-Line Double-Conversion UPS, 9U Rack/Tower, 208/120V or 240/120V Hardwire output
 
Highlights
6000VA / 6kVA / 4200W on-line double-conversion UPS
208/120V or 240/120V 50/60Hz output; Economy mode option
9U Rack/Tower compatible; Hot-swap power and battery modules
RS232 & EPO ports; support for SNMP/WEB card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (3 wire); Hardwire output
Description
Tripp Lite SU6000RT3U on-line, double-conversion UPS protects server, networking or telecommunications equipment from blackouts, voltage
fluctuations and surges in a compact tower/rackmount housing. In a rack configuration, the power module, step-down transformer, and battery pack
occupy only 3 rack spaces each (9U total). Upright tower placement of entire system supported with included tower stands. Large capacity
6000VA/4200 watt power module double-conversion technology converts raw input AC to DC, then resynthesizes it back to perfect sine wave AC
output within 2% of user-selectable 208V/240V and 120V AC output voltages. Frequency regulation locks output power to 50/60Hz (+/-0.2 Hz),
removing harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Perfectly
regulated, continuous sine wave output with zero transfer time offers guaranteed uptime and compatibility with all equipment types. Hardwire input
and output connections support a variety of permanent or PDU style power connections. Highly efficient operation in optional economy mode setting,
saving BTU heat output and energy costs. Battery support can be extended through the addition of external battery packs. Includes accessory slot
for optional monitoring and management cards, plus DB9 contact-closure, and DB9 enhanced serial monitoring ports for unattended shutdown,
remote control and monitoring of UPS system and power data.
Package Includes
SU6000RT3UPM 3U power module
SU6000XFMRRT3U 3U step-down isolation transformer
240V 3U external battery pack
Four post compatible rack rail kit (3 sets)
PowerAlert software, complete data cabling and user manual
Features
Tripp Lite SU60000RT3U 6kVA / 6,000VA / 4200 watt on-line, double-conversion UPS system in 9U total rack/tower configuration (3U UPS
power module, 3U external battery pack and 3U step-down transformer)
Included step-down transformer with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in
output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input and output connections
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions
and line noise
Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with