Powerware Model V-2000B User Manual

Page of 137
 
 
Hard Disk Management = 87 
 
 
Hard Disk Management 
 
This Image Servers employ an advanced Serial-ATA controller that manages four high-
capacity hard disks operating in a RAID-5 configuration.  This design increases system 
performance, and by storing parity data, helps prevent data loss should a drive fail. 
The Image Server brings a high level of reliability to Serial-ATA RAID through a new, 
switched architecture that exceeds the reliability of SCSI shared-bus storage systems.  The earlier 
shared-bus architecture of SCSI has inherent performance limitations due to arbitration latency, 
since only one drive may use the bus at a time.  Further, a single drive failure can bring the entire 
storage system down. 
By contrast, the Image Server uses a non-blocking switched architecture to isolate the drives 
from one another.  Any drive failure makes that drive unavailable and the rest of the storage system 
remains undisturbed.  In addition, the Image Server uses Advanced Data Protection features, where 
all drive commands are checked to ensure that no command corruption has taken place over the 
entire data path. 
Some of the Image Server RAID implementation features and benefits include: 
 
Non-blocking switch technology with RAID 5 parity 
 
On-board processor minimizes host CPU overhead 
 
Easy-to-configure arrays  
 
Dynamic sector repair for robust data protection 
 
Accelerated RAID-5 writes 
About RAID 5 
A RAID 5 configuration features the data striping of RAID 0 combined with the parity benefits of 
RAID 4.  Using a simple parity (exclusive OR) function, RAID 5 can tolerate the loss of one drive.  
Parity information is distributed across all drives rather than being concentrated on a single disk.  
This avoids throughput loss due to contention for the parity drive.  Spare drives can be used to 
rebuild a failed array. 
RAID-5 capacity equals the size of drive times (number of drives -1).  In addition, the array’s 
storage efficiency increases with the number of disks; from 66.7 % for 3 drives to 75 % for 4 