Allied Telesis AT-PWR3202 Leaflet

Page of 2
*613-000397 Rev B*
PN 613-000397 Rev. B
1
2
3
AT-PWR3202 Power Supply Installation Guide
Overview
AT-PWR3202 Power Supply is designed to be installed in an AT-RPS3204 
Redundant Power Supply (RPS). The RPS can supply power to Allied Telesis 
switches if the switch’s main power supply fails
.
Verifying Package Contents
Verify that the correct components are included in your package:
AT-PWR3202 Power Supply
One 21-pin D-combo connector cable
This installation guide
If any item is missing or damaged, contact your Allied Telesis sales 
representative for assistance.
Warranty
The AT-PWR3202 Power Supply has a Lifetime Year Warranty (Five Years 
Power Supply and Fan). For detailed warranty information, see the 
www.alliedtelesis.com website.
Installing the Power Supply
To install an AT-PWR3202 Power Supply, perform the following procedure:
1. Remove the AT-PWR3202 unit from its shipping package and store the 
package in a safe place. You must use the original package if you need to 
return the power supply to Allied Telesis.
2. On the back of the AT-RPS3204 unit, locate the power switch that 
corresponds to the slot where you are going to install the power supply and 
verify that the On/Off button is in the Off (out) position. From left to right on 
the back, the power supplies are identified as B2, B1, A2, A1. (An AT-
RPS3204 is shipped with one AT-PWR3202 in the slot marked A1.)
3. Using a Phillips head screwdriver, remove the cover from the slot in the front 
of the AT-RPS3204 unit where you want to install the power supply.
Note
As an example, the following steps show an AT-PWR3202 unit installed in 
slot A2 of the AT-RPS3204 Redundant Power Supply.
Keep the slot cover in a safe area in case you remove a power supply. The 
slot cover helps maintain proper air flow through the RPS.
4. Slide the AT-PWR3202 Power Supply into the slot
5. Use a Phillips head screwdriver to tighten the captive screws.
6. On the back of the AT-RPS3204 unit, plug one end of the 21-pin D-combo 
connector cable into the connector that corresponds to the slot in which you 
installed the AT-RPS3202 Power Supply.
7.
Tighten the captive screws.
892
STA
TUS
POWER
FAULT
AT-PW
R3202
12VDC 
    ,16.6A MA
X
STATUS
POWE
R
FAULT
STATUS
POW
ER
FAULT
893
AT-PW
R320
2
12VDC
     ,16.6A 
MAX
STATUS
POWER
FAULT
STATUS
POWER
FAULT
894
STATU
S
POWER
FAUL
T
AT-PW
R320
2
12VD
C     ,16.6A
 MAX
AT-PW
R320
2
12VD
C     
,16.6A
 MAX
STATUS
POW
ER
FAULT
STATUS
POWER
FAULT
895
STATUS
POWER
FAUL
T
AT-PW
R3202
12VD
C     ,16
.6A MA
X
AT-PWR3202
12V
DC   
  ,16.6A 
MAX
198
RPS O
UTPU
T A2
12VDC      
  
RPS O
UTPU
T A1
12VDC        
AC INPUT A
2/A1
100 - 240 
VAC 
~
ON
OFF
ON
OFF
A1
A2
199
RPS OUTPU
T A2
12VDC        
RPS OUTPU
T A1
12VDC       
 
AC INPUT A2/A
1
100 - 240 
VAC 
~
ON
OFF
ON
OFF
A1
A2