B&K 0-3A User Manual

Page of 58
 
SPECIFICATIONS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
OUTPUT VOLTAGE: 
0 to 30VDC, coarse and fine 
adjustment. 
 
OUTPUT CURRENT: 
0 to 3A, coarse and fine adjustment. 
 
CONSTANT VOLTAGE OPERATION 
 
Voltage Regulation 
Line (108-132 V): 
0.01% + 3mV. 
Load (no load to full load): 
0.01% + 3mV. 
 
Recovery Time: 
100 µs typical. 
 
Ripple Voltage 
Peak-to-Peak: 
2mV, typical 
RMS: 
1mV. 
 
Temperature Coefficient 
(0° to +35 °C):  
300 PPm/°C 
 
CONSTANT CURRENT OPERATION 
 
Adjustable Current Limits: 
5% to 100% 
Current Regulation 
 
Line (108-132 V): 
0.2% + 3mA 
Load 
0.2% + 3mA 
 
Current Ripple: 
3mA typical. 
 
METERING 
 
Voltmeter 
4 digit Green LED Display 
Range: 
0 to 99.99 V. 
Accuracy: 
(0.5% + 9 digits)*. 
 
Ammeter 
4 digit Red LED Display  
Range: 
0 to 9.999A. 
Accuracy: 
(0.5% + 9 digits)*. 
(* = see note 1 at end of specifications) 
 
POWER REQUIREMENTS:  
 
Domestic: 120 VAC ±10%, 60 Hz 
International: 120/220/230/240 VAC - 10%, 50/60 Hz 
 
POWER CONSUMPTION: 
Approximately 180W or less at 
full load. 
 
PROTECTION: 
Reverse polarity protection,  
 
 
Current limiting.